HP Integrity rx1620 Installation Guide, Second Edition - HP Integrity rx1620 - Page 67
Table 4-18, Processor Faults, Table 4-19, BMC Faults, Table 4-20, Temperature Faults
View all HP Integrity rx1620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Troubleshooting Identifying and Diagnosing Hardware Problems a. Refer to the hp Integrity rx1620 Maintenance Guide for detailed instructions on the maintenance action. Table 4-18 Processor Faults System LED Flashing Red Flashing Red Flashing Red LED 1 LED 2 LED 3 Red Red Green Red Red Off Red Red Green LED 4 Problem Solution Off Green Green Processor 0 temperature exceeds limit Processor 1 temperature exceeds limit Make sure nothing is blocking the system's airflow and locate your system in an air-conditioned room. In a single CPU configuration, verify that the airflow blocker is installed. No processor detected. Verify that the processor or processors are correctly installed. See Chapter 3, Installing and Configuring, for installation procedures. Table 4-19 BMC Faults System LED Flashing Red Flashing Red LED 1 LED 2 Red Green Red Green LED 3 LED 4 Problem Solution Red Off BMC firmware is damaged Turn off and unplug the system. Wait 20 seconds, then plug in and restart the system. If the error repeats, replace the base unit. Red Green System Replace the base unit. board FRU inventory device inaccessible Table 4-20 Temperature Faults System LED Flashing Red LED 1 LED 2 Red Green LED 3 Green LED 4 Problem Solution Red External air Make sure nothing is blocking temperature the system's airflow and locate too high your system in an air-conditioned room. Chapter 4 67