HP Integrity rx1620 Installation Guide, Second Edition - HP Integrity rx1620 - Page 66
Table 4-15, Firmware Errors, Table 4-16, System Board Faults, Table 4-17, Fan Faults, Table 4-14,
View all HP Integrity rx1620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Troubleshooting Identifying and Diagnosing Hardware Problems Table 4-14 Memory Faults (Continued) System LED Flashing Red LED 1 LED 2 Red Green LED 3 Green LED 4 Problem Solution Green Bad Memory. One or more DIMMs are bad or not seated properly. Reseat the DIMMs. If the error persists, replace them. Table 4-15 Firmware Errors System LED Flashing Red LED 1 LED 2 LED 3 LED 4 Problem Off Red Off Off System Firmware Hang Solution View the SEL for additional information. For further assistance, contact your HP Support Engineer. Table 4-16 System Board Faults System LED Flashing Red Flashing Red LED 1 LED 2 LED 3 LED 4 Problem Off Green Red Off VRM overvoltage Green Off Red Off VRM undervoltage Solution View the SEL for additional information. For further assistance, contact your HP Support Engineer. View the SEL for additional information. For further assistance, contact your HP Support Engineer. Table 4-17 Fan Faults System LED Flashing Red Flashing Red Flashing Red LED 1 LED 2 LED 3 LED 4 Problem Solution Green Off Off Red Off Green Off Red Off Off Green Red Cooling Unit Replace the fan that is not 1 (PSU) fault functioning.a Cooling Unit 2 (memory) fault Replace the fan that is not functioning.a Cooling Unit Replace the fan that is not 3 (CPU) fault functioning.a 66 Chapter 4