HP ProLiant DL380p HP ProLiant Servers Troubleshooting Guide - Page 125

Fan Solution Not Sufficient, Fatal DMA Error, Fatal Express Port Error, Fatal Front Side Bus Error,

Page 125 highlights

Fan Solution Not Sufficient Audible Beeps: Possible Cause: The minimum number of required fans is missing or failed. Action: Install fans or replace any failed fans. Fatal DMA Error Audible Beeps: None Possible Cause: The DMA controller has experienced a critical error that has caused an NMI. Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 77) and replace failed components as indicated. Fatal Express Port Error Audible Beeps: None Possible Cause: A PCI Express port has experienced a fatal error that caused an NMI. Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 77) and replace the failed PCI Express boards or reseat loose PCI Express boards. Fatal Front Side Bus Error Audible Beeps: None Possible Cause: The processor front-side bus experienced a fatal error. Action: 1. Run Insight Diagnostics ("HP Insight Diagnostics" on page 77). CAUTION: Before replacing or reseating any processors, be sure to follow the guidelines provided in "Performing processor procedures in the troubleshooting process (on page 18)." Failure to follow the recommended guidelines can cause damage to the system board requiring replacement of the system board. 2. Replace any failed processors or reseat any loose processors. Fatal Global Protocol Error Audible Beeps: None Possible Cause: The system experienced a critical error that caused an NMI. Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 77) and replace failed components as indicated. Error messages 125

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Error messages 125
Fan Solution Not Sufficient
Audible Beeps
:
Possible Cause
: The minimum number of required fans is missing or failed.
Action
: Install fans or replace any failed fans.
Fatal DMA Error
Audible Beeps
: None
Possible Cause
: The DMA controller has experienced a critical error that has caused an NMI.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace failed components as
indicated.
Fatal Express Port Error
Audible Beeps
: None
Possible Cause
: A PCI Express port has experienced a fatal error that caused an NMI.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace the failed PCI Express
boards or reseat loose PCI Express boards.
Fatal Front Side Bus Error
Audible Beeps
: None
Possible Cause
: The processor front-side bus experienced a fatal error.
Action
:
1.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
).
CAUTION:
Before replacing or reseating any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
18
)."
Failure to follow the recommended guidelines can cause damage to the system board requiring
replacement of the system board.
2.
Replace any failed processors or reseat any loose processors.
Fatal Global Protocol Error
Audible Beeps
: None
Possible Cause
: The system experienced a critical error that caused an NMI.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace failed components as
indicated.