HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358,
HP StorageWorks 1606 - Extension SAN Switch Manual
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 1606 manual content summary:
- HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 1
HP StorageWorks Fabric OS 6.3.0 release notes Part number: 5697-0358 Third edition: March 2010 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 2
Legal and notice information © Copyright 2009-2010 Hewlett-Packard Development Company, L.P. © Copyright 2009-2010 Brocade Communications Systems, Incorporated - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 3
; 10-GbE ports require 10-GbE B-series SFPs.) • HP StorageWorks 1606 Extension SAN Switch, the next-generation distance extension platform for FCIP applications, supports 16 FC ports at 1, 2, 4, and 8 Gb/s, and 6 1-GbE optical ports. (The user can select either a copper or optical interface on two - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 4
APC auto detection of connection to M-series switch as N_Port connection • Encryption platform enhancements • System card support • Quorum card support for multi-admin-based authorization of sensitive operations • HP tape encryption support • Support for multipath through a single encryption engine - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 5
on the DC SAN Director Multi-protocol Extension Blade and 1606 Extension SAN Switch that virtualizes two users to establish flow-based prioritization of traffic over a SAN. Fabric OS 6.3 extends QoS over FCR configurations, allowing support of QoS for traffic flows originating in an HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 6
can view historic statistics logs for the port to investigate the problem. This new capability is considered part of the Adaptive Networking Base Offset settings. NOTE: See the Merging Fabrics Based on M-Series and B-Series FC Switches application note for specific information on what HP supports - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 7
all 8-Gb platforms. • Integrated Routing license-Allows ports on a DC SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to be configured as EX_Ports, supporting FCR. This eliminates the need to add a Bseries Multi - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 8
on the 1606 Extension SAN Switch and DC SAN Backbone Director/DC04 SAN Director for the DC SAN Director Multi-protocol Extension Blade on the disabling of FC ports after the upgrade. Contact HP Support to obtain this license key if your 2408 switch does not already have it installed. • FCoE-This - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 9
supported by Fabric OS 6.0.x can be upgraded to Fabric OS 6.3.0, with the exception of the following switches: • HP StorageWorks 4/8 SAN Switch • HP StorageWorks 4/16 SAN Switch • Brocade 4Gb SAN Switch for HP p-Class BladeSystem • Brocade 4Gb SAN Switch for HP c-Class BladeSystem HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 10
SFPs, and 10-GbE ports require 10-GbE B-series SFPs. • 1606 Extension SAN Switch-Next-generation distance extension platform for FCIP applications. Supports 16 FC ports at 1, 2, 4, and 8 Gb/s, and 6 1-GbE optical ports. (The user can select either a copper or optical interface on two ports.) GbE - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 11
8-Gb SAN Switch for HP BladeSystem c-Class (Brocade 5480) • HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) • HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) • HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE10-24) • HP StorageWorks DC SAN Director - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 12
Switch for HP c-Class BladeSystem (Brocade 4024) • HP StorageWorks 8/80 SAN Switch • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director • HP StorageWorks 400 Multi-protocol Router • HP StorageWorks EVA4400 Embedded Switch Module • HP StorageWorks 1606 Extension SAN Switch - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 13
into the base Fabric OS, HP website: http://www.hp.com IMPORTANT: The Fabric OS versions listed in the Earliest compatible version column in Table 1 are the earliest versions supported by HP for connection to switches running Fabric OS 6.3.0 at the time of the Fabric OS 6.3.0 release. HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 14
support ended December 2007) N/A HP StorageWorks MSA SAN Switch 2/8 3.2.1c 3.2.1c1,6,7 HP StorageWorks Core Switch 2/64 HP StorageWorks SAN Director 2/128 in Chassis 5.0.5e Config modes 3 and 4 only 5.0.5f6,7 HP StorageWorks SAN Switch 2/8V HP StorageWorks SAN Switch 2/16V HP StorageWorks SAN - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 15
0f 6.3.0 HP StorageWorks 8/8 SAN Switch HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 6.1.0f 6.3.05 HP StorageWorks Encryption SAN Switch 6.2.0b 6.3.0 HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.0 HP StorageWorks 2408 FCoE - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 16
not be used with XPath or Fabric OS-based routing (FCR) for connections to the same edge fabric. 9 When attempting to use HP StorageWorks Fabric Manager (FM) v5.5 and lower with Fabric OS (FOS) v6.1.1 and higher, users may encounter problems with Zoning, Performance monitoring, SYSLOG configuration - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 17
requires Fabric OS 6.2.0a or later, and supports up to four blades. FS8-18 (DC Switch Encryption FC blade) Supported with Fabric OS 6.2.0b or later, with a maximum of four blades of this type on the DC SAN Backbone Director or DC04 SAN Director HP StorageWorks Fabric OS 6.3.0 release notes 17 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 18
Director blade Number of blades FX8-24 (DC SAN Director Multi-protocol Extension Blade) FCOE10-24 (DC SAN Director Switch 10/24 FCoE Blade) Supported with Fabric OS 6.3.0 with a maximum of two blades per director. The DC SAN Director Switch 10/24 FCoE Blade can be installed in the same chassis - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 19
.2 1The FC blades in this row are the only ones supported in the DC SAN Backbone Director or DC04 SAN Director with 110 VAC power supplies. 2110 VAC is not supported in either the DC SAN Backbone Director or DC04 SAN Director with these blades. HP StorageWorks Fabric OS 6.3.0 release notes 19 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 20
Fibre Channel Routing scalability For the latest information about Fibre Channel Routing (FCR) scalability support, see the HP StorageWorks SAN design reference guide, available at: http://www.hp.com/go/sandesignguide 20 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 21
EFCM nor FM are qualified or supported for management of switches operating with FOS v6.3.x firmware. SAN Switch or DC Switch Encryption FC Blade, switches that are attached to hosts and targets or that are part of the encryption flow must operate at the following minimum levels: HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 22
must operate with Fabric OS 6.1.0f, 6.1.1b, or later. • M-EOS-based platforms must operate with M-EOS 9.8.1 or later for McDATA Fabric Mode (in- for Open Fabric Mode (interopmode 3). Web Tools compatibility • Fabric OS 6.3 is supported with JRE 1.6.0 Update 13. • If the JRE 1.6.0 version is not - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 23
connectivity modes for deployment with M-EOS-based products. All HP StorageWorks models supported by Fabric OS 6.3.0 support both interopmodes 2 and 3, with the exception of the 4/32 SAN Switch, 2408 FCoE Converged Network Switch, and DC SAN Backbone Director or DC04 SAN Director with one or more DC - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 24
Extended Fabrics Alias Server Platform Service FCIP (VE_Ports) IPFC (IP over FC) M-EOS ALPA 0x13 configuration VE_Port to VEX_Port Integrated Routing9 Domain Offset Support 239 Domain Support (available on Mi10K only) Masterless F_Port Trunking (AG connect to Fabric OS switches only) FC10-6 to FC10 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 25
policy also reduces the number of upgrade-downgrade permutations that must be tested, allowing for thorough testing and verification of supported migration paths. The DC04 SAN Director cannot be downgraded to a release earlier than Fabric OS 6.2.0a. HP StorageWorks Fabric OS 6.3.0 release notes 25 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 26
SAN Switch cannot be downgraded to a version earlier than Fabric OS 6.2.0b. If there are multiple node encryption groups (EGs) in a fabric, complete the firmware download on one node at a time before downloading on another node. Firmware upgrade instructions IMPORTANT: HP recommends that users - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 27
Switch/DC SAN Director Multi-protocol Extension Blade and another 1606 Extension SAN Switch/DC SAN Director Multiprotocol Extension Blade. FCIP tunnels are not supported between the 1606 Extension SAN Switch/DC SAN Director Multi-protocol Extension Blade and the previous generation HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 28
and 3 require the slot-based 10-GbE FCIP license. • ARL is not supported on 10-Gb tunnels. • IPv6, IPsec, DiffServ VLAN tagging, and In-band Management are not supported on the 1606 Extension SAN Switch or DC SAN Director Multi-protocol Extension Blade. • Fabric OS 6.3 supports only up to four 1-Gb - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 29
time and 0.1% loss • The 1606 Extension SAN Switch supports optical and copper media types on GE0 switches having different OUI indexes from the eight assigned to Brocade (for example, 00051E and 006069), WWNs can differ in more than three bytes. In this case, after a normal merge and HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 30
with HP StorageWorks DC SAN or DC04 SAN Directors with one or more DC SAN Director Switch 10/ supported on the 1606 Extension SAN switch. • VF-dedicated ISLs are supported on the DC SAN Director Switch Multiprotocol Extension Blade. XISLs are not supported. Licensing behavior When operating a switch - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 31
up after 6.0 is running on those switches. • Flow-based QoS is not supported on any 8-Gb Fibre Channel blades in the 4/256 SAN Director. • Any products that cannot operate with Fabric OS 6.0 cannot exist in a fabric with flow-based QoS. Major problems occur if previous-generation 2-Gb products exist - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 32
SAN Switch when using Integrated Routing, the edge switch connected to the 8/40 SAN Switch must be running Fabric OS 6.1 or later. • Integrated Routing EX_Ports are supported only in the base switch on a switch to M-EOS switches. M-EOS ports should be set to G_Port to prevent problems with port-type - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 33
may cause evm errors, so each new switch should be isolated from supported on the 1606 Extension SAN Switch. 10G interoperability 10G interoperability between the HP StorageWorks SAN Director 6 Port 10Gb FC Blade and McDATA blades is not supported due to a hardware limitation. However, the SAN - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 34
Time Division Multiplexor (TDM). To overcome this limitation and provide support for frame-based trunking with Extended Fabrics, Fabric OS 6.2.x and later has been enhanced to support interoperability with these distance extension devices. Fabric OS 6.3.0 allows Extended Fabrics E_Ports to operate - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 35
to an extension device that does not support ARB primitives the new 8-Gb devices have problems with the Idle/Idle sequence at 8 Gb. 8-Gb switches, HBAs, and smaller mid- the portCfgShow command to display user-configured fill-word settings. The HP StorageWorks Fabric OS 6.3.0 release notes 35 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 36
a port to ARBFF-ARBFF: switch:admin> portcfgfillword 2/3, 1 See also the portCfgShow command in the Fabric OS Command Reference Manual. • Behavior: • Default mode the Idle implementation. The new portCfgFillWord command enables the user to configure the ARB configuration. • Existing product For - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 37
, DC04 SAN Director, or 4/256 SAN Director running Fabric OS 6.3 in interopmode 2, the console log may generate continuous Unknown LSR type messages. You must either reboot the switch to terminate these messages, or another hafailover issued will also terminate the messages. HP StorageWorks Fabric - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 38
> Events Monitor > Reports > Fabric Reports > Fabric summary Summary report FCIP tunnel configuration Port Admin Module > GigE tab Configure > FCIP tunnel Viewing FCIP tunnels is still supported in Web Tools 6.1.1, but New, Edit Config, and Delete are available only in DCFM. 38 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 39
to this LUN configuration process: If the LUN was previously encrypted by the HP Encryption Switch or HP Encryption Blade, the LUN can be added to the CTC with the -encrypt an Encryption Enabled state before committing additional LUN modifications. HP StorageWorks Fabric OS 6.3.0 release notes 39 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 40
, the new KAC Certificate must be loaded onto key vaults for (SKM. Without this step, errors will occur, such as key vault not responding and ultimately key archival and retrieval problems. • The HTTP server should be listening to port 9443. SKM is supported only when configured to port 9443. 40 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 41
different media types on a single encryption engine (Encryption SAN Switch or Encryption FC blade) is not supported. Encryption FC blades can be configured to support different media types within a common DC SAN Director/DC04 SAN Director chassis. HP StorageWorks Fabric OS 6.3.0 release notes 41 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 42
with Multiple Nodes and Dual SKM Key Vaults. Two-way certificate exchange is supported. See the Encryption Admin Guide for configuration information. If you are using dual SKMs on Encryption SAN Switch/Encryption FC blade Encryption Group, these SKM Appliances must be clustered. Failure to cluster - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 43
can refer to the Configuring the Key Manager section in the SKM user guide. NOTE: According to the FIPS requirements, you cannot enable or example). • For HP-UX, LUN 0 can appear as 0x0 or 0x400, but both of them are LUN 0 only and should be treated alike. HP StorageWorks Fabric OS 6.3.0 release - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 44
rebooting the HP StorageWorks Encryption SAN Switch that has no longer zoned together, then the user should also remove the associated container switch. Applications that write to a LUN that is being rekeyed may see I/O errors Interopmode 2 default zone is not supported. NPIV devices should be part - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 45
change: Follow the raslog errors FABR-1044 or FABR-1043 displayed by switches in the fabric to identify the offending switch and resolve the FID switch disable. HA cluster member node, HP StorageWorks Encryption SAN Switch faults as a result of slot powercycling its HA cluster peer (HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 46
user password is NOT generated as seen from the console log, thereby causing a NO COMM on the VCM. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Power off and Power on the Switch via OA should fix the problem. Swapping HP StorageWorks 32 port 8Gb FC blade with 48 port blade in DC04 SAN - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 47
HP VC switch from Bay 3 and installed in Bay 4 Fixed in Fabric OS 6.3.0 Channel receiving RSCN with missing ports in payload after HPF key Fixed in Fabric OS 6.3.0 on or off. Software verify error occurred during supportsave on HP StorageWorks Fixed in Fabric OS 6.3.0 DC SAN Backbone & DC04 SAN - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 48
Fixed in Fabric OS 6.3.0 causes one of the Encryption SAN Switches to go into faulty state. Command "fddcfg -fabwideset" and other security commands fails with RCS transaction error. Fixed in Fabric OS 6.3.0 With tape pipelining active, the switch may return a good status without Fixed in Fabric - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 49
database. After rebooting one Encryption SAN Switch of a HAC that has error code "105" showing up on most platforms in AG fabrics. Possible Memory Leak scenarios. Fixed in Fabric OS 6.3.0 RLIRs with LOL is being generated on 8Gb channels during CEC IML Fixed in Fabric OS 6.3.0 HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 50
error: ERROR, SYS, Crypto tape receives service failure in tape_cmd_pre_execution_scsi_chk: PI BLK size > RBL, 0x0, Fixed in Fabric OS 6.3.0 tape_util.c, line: 5002. User SAN Switch goes to 'faulty' state after test cycle that alternately reboots each Encryption SAN Switch after the problem has - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 51
SAN Switch power cycle. Fixed in Fabric OS 6.3.0 Out of Memory due to switch not timing out in.telnetd processes. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot the switch. Transmitted Rate / Received rates based RTWR error when HP StorageWorks Fabric OS 6.3.0 release notes 51 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 52
SAN Switch for HP c-Class BladeSystem AG may login to DC SAN Director with wrong pwwn. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot AG. OpenVMS init command is not correctly supported isolated / spurious High Temperature CRITICAL errors when not preceeded by warnings. Unable - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 53
configdownload problems. SAN switch for HP c-Class BladeSystem in Access Gateway-mode lost their targets when failover happened from 1 trunk group (with primary ports) to another trunk group (with shared area ports) on 8Gb 48 port blade of DC SAN Director. Fixed in Fabric OS 6.3.0 HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 54
getting reflected in Port Admin window. Confusing error message when copying a source configuration from Fixed in Fabric OS 6.3.0 Web Tools Switch Admin: QoS: User defined priority group 0-7 does not show up 6.2.0c when XISL use is enabled base logical switch in switchshow shows Allow XISL Use as - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 55
. Containers for 4/32B SAN Switch not ready for discover LUN. Fixed in Fabric OS 6.3.0 FOS 6.2 Radius Calling-station-ID (31) implementation is used for both Fixed in Fabric OS 6.3.0 "device called by" and "workstation called from" hostname/IP address. HP StorageWorks Fabric OS 6.3.0 release - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 56
accessible on 8GB SAN Switch for HP BladeSystem c- Fixed in Fabric OS 6.3.0 Class. Blade fault observed with a 4/256 SAN Director chassis CLI. Encryption SAN Switch and Encryption FC blade do not support en- Fixed in Fabric OS 6.3.0 crypted LUNs >2TB. Switch Admin: Proper error message should - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 57
-s and then do a manual reboot. 2. Need to power cycle the switch. The switch functions properly after power cycle with SAN Switch: Removing any power supply FRU causes fans to speed up for a short period (which is not expected). Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 58
stuck. Fixed in Fabric OS 6.3.0 DC SAN Director: configdownload: simple upload/download (switch enabled) complaining about FID 128 and will not download with Fixed in Fabric OS 6.3.0 switch enabled. Switch Admin: CEE: NPE is shown in error message when user applies a new FCoE login group (with - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 59
switches and setting idid mode in the switch configurations, then bringing the switches online. This option is applicable only in the event the user wishes to merge the switch media outside of the Encryption SAN Switch and then continue on with label. HP StorageWorks Fabric OS 6.3.0 release notes 59 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 60
open. Ports were found disabled after enabling Virtual Fabric (VF) through DCFM on 8/40 SAN Switch. Fixed in Fabric OS 6.3.0 Fabric watch: (java.lang.illegalArgumentException:Invalid logid) error message box will appear when selecting Configuration report sub-tab Fixed in Fabric OS 6.3.0 under - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 61
DC SAN Director CP fails over non-disruptively and retains all configuration data. 4Gb switch running at fixed 2Gb speed may not respond to FLOGI from HBA using auto-speed negotiation. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Lock the port to fixed speed. HP StorageWorks Fabric - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 62
SAN Director with 8 logical switches. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Wait for system to stabilize after executing bladedisable and before issuing hafailover or disable MS platform services is not on the LF role list, the user cannot login. Fixed in Fabric OS 6.3.0 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 63
" button in the "Service" tab of "HA" window is clicked. Fixed in Fabric OS 6.3.0 High Availability: The error message thrown is not Switch. Fixed in Fabric OS 6.3.0 Unexpected software call traceback error messages are being displayed on the console. Fixed in Fabric OS 6.3.0 HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 64
part of a 256 area type that does not support auto mode. Fixed in Fabric OS 6.3.0 Data miscompare user configured key ID without commit, CAL doesn't return key ID value. Fixed in Fabric OS 6.3.0 Auditcfg does not generate RBAC permission denied messages. Fixed in Fabric OS 6.3.0 4Gb SAN Switch - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 65
in Fabric OS 6.3.0 RTWR max retries exhausted on DC04 SAN Director after stress test Fixed in Fabric OS 6.3.0 with If user selects authentication type as "all", in interop modes the default authentication type is still FCAP between FOS switches. HP StorageWorks Fabric OS 6.3.0 release notes 65 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 66
Encryption blade turns faulty 21 after firmwaredownload and reboot of DC SAN Director. Fixed in Fabric OS 6.3.0 Workaround prior to code change enabled, the user can activate only 2047 Zones per Zone Set. Fixed in Fabric OS 6.3.0 Event for change in IDID state on neighboring switch not being - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 67
Switches in Fabric during Configupload on Single FOS Switch in a Interopmode 2 fabric. Fixed in Fabric OS 6.3.0 Block user from configuring QoS on 6-port 10Gb ISL blade. Fixed in Fabric OS 6.3.0 Inappropriate error and re-install EE Monitors. HP StorageWorks Fabric OS 6.3.0 release notes 67 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 68
error message. IP monitor shows number of SCSI frames after deleting a SCSI filter monitor and adding IP monitor on the same port. Onboard Administrator used to manage 8Gb SAN Switch Fabric OS 6.3.0 = 115, user mode" and termination of ficud. required to better support snmp mib. some services. - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 69
commit) cause hacluster failover even the (container Fixed in Fabric OS 6.3.0 owner) switch is still disabled. Error message may be seen on console under heavy utilization of in- Fixed in initially when the page loads. Fixed in Fabric OS 6.3.0 HP StorageWorks Fabric OS 6.3.0 release notes 69 - HP StorageWorks 1606 | HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 70
70
HP StorageWorks Fabric OS 6.3.0
release notes
Part number: 5697-0358
Third edition: March 2010