HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 45

After changing FID on HP StorageWorks 8/40 SAN Switch and then, HA cluster member node

Page 45 highlights

In a mixed fabric of VF enabled and non-VF switches, a VF enabled switch may not be able to detect the FID conflict with the other VF enabled switch, if there are non-VF switches in the path interconnecting the VF enabled switches. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Follow the raslog errors FABR-1044 or FABR-1043 displayed by switches in the fabric to identify the offending switch and resolve the FID conflict. IPC message from module CALD to Management Server is dropped Fixed in Fabric OS 6.3.0 by Management server. This causes CALD module to wait indefinitely. Sometimes config file downloaded may cause the configdownload command to crash. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Disable the switch and then attempt configdownload. After changing FID on HP StorageWorks 8/40 SAN Switch and then performing switchenable, switchdisable, observed ASSERT. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Do not disable a switch immediately after enabling, if it's coming up with a new FID for the first time. Wait for sometime (at least 10 s) before issuing switch disable. HA cluster member node, HP StorageWorks Encryption SAN Switch faults as a result of slot powercycling its HA cluster peer (HP StorageWorks DC Encryption FC Blade). Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot the Encryption SAN Switch. IPL file is not getting updated, when a PDCM matrix is activated using Fixed in Fabric OS 6.3.0 Web Tools with "Active=Save Mode" checked. Fabric Watch failed to initialize on fully populated HP StorageWorks Fixed in Fabric OS 6.3.0 DC SAN Backbone Director. Memory leak when querying connUnitPortFCId in Access Gateway (AG) mode and also when querying FcFeModuleName. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Avoid querying FcFeModuleName or (connUnitPortFCId in AG mode) MIB to avoid memory leak. Occasionally during the firmware upgrade process, the 1250 processor is still rebooting when the FCR routes are being processed, resulting Fixed in Fabric OS 6.3.0 in missing FCR routes and an inability to route traffic across VEX ports. CUP Port present CU-Busy on one path and never sending CU-End to Fixed in Fabric OS 6.3.0 clear busy. In B2E routed environment, when user executes Pathinfo command in Fixed in Fabric OS 6.3.0 BB querying for xlate domain, the switch may panic. Observed kernel panic on a DC SAN Backbone Director in RTE module. Fixed in Fabric OS 6.3.0 Switches leaking memory slowly over extended period while being managed by DCFM. Fixed in Fabric OS 6.3.0 Switchdisabling all switches in the fabric causing all HP StorageWorks 4/256 SAN Director switches 'Out of Memory: Killed process 2337 Fixed in Fabric OS 6.3.0 (iswitchd)'. HP StorageWorks Fabric OS 6.3.0 release notes 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Follow the raslog errors FABR-1044
or FABR-1043 displayed by switches
in the fabric to identify the offending
switch and resolve the FID conflict.
In a mixed fabric of VF enabled and non-VF switches, a VF enabled
switch may not be able to detect the FID conflict with the other VF en-
abled switch, if there are non-VF switches in the path interconnecting
the VF enabled switches.
Fixed in Fabric OS 6.3.0
IPC message from module CALD to Management Server is dropped
by Management server. This causes CALD module to wait indefinitely.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Disable the switch and then attempt
configdownload.
Sometimes config file downloaded may cause the configdownload
command to crash.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not disable a switch immediately
after enabling, if it's coming up with
a new FID for the first time. Wait for
sometime (at least 10 s) before issuing
switch disable.
After changing FID on HP StorageWorks 8/40 SAN Switch and then
performing switchenable, switchdisable, observed ASSERT.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Reboot the Encryption SAN Switch.
HA cluster member node, HP StorageWorks Encryption SAN Switch
faults as a result of slot powercycling its HA cluster peer (HP Storage-
Works DC Encryption FC Blade).
Fixed in Fabric OS 6.3.0
IPL file is not getting updated, when a PDCM matrix is activated using
Web Tools with "Active=Save Mode" checked.
Fixed in Fabric OS 6.3.0
Fabric Watch failed to initialize on fully populated HP StorageWorks
DC SAN Backbone Director.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Avoid querying FcFeModuleName or
(connUnitPortFCId in AG mode) MIB
to avoid memory leak.
Memory leak when querying connUnitPortFCId in Access Gateway
(AG) mode and also when querying FcFeModuleName.
Fixed in Fabric OS 6.3.0
Occasionally during the firmware upgrade process, the 1250 processor
is still rebooting when the FCR routes are being processed, resulting
in missing FCR routes and an inability to route traffic across VEX ports.
Fixed in Fabric OS 6.3.0
CUP Port present CU-Busy on one path and never sending CU-End to
clear busy.
Fixed in Fabric OS 6.3.0
In B2E routed environment, when user executes Pathinfo command in
BB querying for xlate domain, the switch may panic.
Fixed in Fabric OS 6.3.0
Observed kernel panic on a DC SAN Backbone Director in RTE module.
Fixed in Fabric OS 6.3.0
Switches leaking memory slowly over extended period while being
managed by DCFM.
Fixed in Fabric OS 6.3.0
Switchdisabling all switches in the fabric causing all HP StorageWorks
4/256 SAN Director switches 'Out of Memory: Killed process 2337
(iswitchd)'.
HP StorageWorks Fabric OS 6.3.0 release notes
45