HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 57
In Access gateway mode,Port swap and Enable/Disable NPIV option
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Switch panic when supportsave read invalid data on GE ports without Fixed in Fabric OS 6.3.0 FC Fastwrite enabled. Firmware downgrade from FOS v6.2.0 to v6.1.0 sometimes causes an unresponsive console, which requires a switch power cycle to recover. Fixed in Fabric OS 6.3.0 Workaround prior to code change: 1. Avoid using firmwaredownload -sb i.e. avoid auto-reboot. Use firmwaredownload -s and then do a manual reboot. 2. Need to power cycle the switch. The switch functions properly after power cycle with normal access to the telnet session. Rekeyed LUNs are in "Not Ready (Getting key from archive)" state when the key vault goes down and does not recover. Web Tools Zone Admin "Add member" button is always disabled. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Workaround prior to code change: Add members with the "Add other" button. In non-VF mode on DC SAN Director, after removing other filters (EE and F_Port TT) and enabling Fabric mode TopTalkers, the flow values are not reliable. Fixed in Fabric OS 6.3.0 HA Failover on DC SAN Director caused: Need to reboot the system for recovery, reason: System bring up timed out. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Mannually block and unblock an E_Port to rebuild the fabric. In Access gateway mode,Port swap and Enable/Disable NPIV option Fixed in Fabric OS 6.3.0 is enabled in Web Tools. As DCFM polling LUNs, the memory usage for weblinker is increased. Fixed in Fabric OS 6.3.0 FDMI: fdmid crashes when a brocade HBA with virtual ports is connected to a 4/256 SAN Director. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Logout all the devices registered their HBA info and log them in after the fabric is stable. Brocade 8000 firmware download hot code load shows no identifier Fixed in Fabric OS 6.3.0 in the HTML page. Unable to activate a new PDCM Matrix with Webtools. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Activate the same PDCM Matrix from WebTools, with "Active=Save Mode" checked from 'Edit CUP Port Connectivity Configuration' window. VCM don't have GUI capability to change SNMP read community configuration. 8/80 SAN Switch: Removing any power supply FRU causes fans to speed up for a short period (which is not expected). Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 HP StorageWorks Fabric OS 6.3.0 release notes 57