HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 57

In Access gateway mode,Port swap and Enable/Disable NPIV option

Page 57 highlights

Switch panic when supportsave read invalid data on GE ports without Fixed in Fabric OS 6.3.0 FC Fastwrite enabled. Firmware downgrade from FOS v6.2.0 to v6.1.0 sometimes causes an unresponsive console, which requires a switch power cycle to recover. Fixed in Fabric OS 6.3.0 Workaround prior to code change: 1. Avoid using firmwaredownload -sb i.e. avoid auto-reboot. Use firmwaredownload -s and then do a manual reboot. 2. Need to power cycle the switch. The switch functions properly after power cycle with normal access to the telnet session. Rekeyed LUNs are in "Not Ready (Getting key from archive)" state when the key vault goes down and does not recover. Web Tools Zone Admin "Add member" button is always disabled. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Workaround prior to code change: Add members with the "Add other" button. In non-VF mode on DC SAN Director, after removing other filters (EE and F_Port TT) and enabling Fabric mode TopTalkers, the flow values are not reliable. Fixed in Fabric OS 6.3.0 HA Failover on DC SAN Director caused: Need to reboot the system for recovery, reason: System bring up timed out. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Mannually block and unblock an E_Port to rebuild the fabric. In Access gateway mode,Port swap and Enable/Disable NPIV option Fixed in Fabric OS 6.3.0 is enabled in Web Tools. As DCFM polling LUNs, the memory usage for weblinker is increased. Fixed in Fabric OS 6.3.0 FDMI: fdmid crashes when a brocade HBA with virtual ports is connected to a 4/256 SAN Director. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Logout all the devices registered their HBA info and log them in after the fabric is stable. Brocade 8000 firmware download hot code load shows no identifier Fixed in Fabric OS 6.3.0 in the HTML page. Unable to activate a new PDCM Matrix with Webtools. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Activate the same PDCM Matrix from WebTools, with "Active=Save Mode" checked from 'Edit CUP Port Connectivity Configuration' window. VCM don't have GUI capability to change SNMP read community configuration. 8/80 SAN Switch: Removing any power supply FRU causes fans to speed up for a short period (which is not expected). Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 HP StorageWorks Fabric OS 6.3.0 release notes 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Fixed in Fabric OS 6.3.0
Switch panic when supportsave read invalid data on GE ports without
FC Fastwrite enabled.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
1.
Avoid using firmwaredownload -sb
i.e. avoid auto-reboot. Use
firmwaredownload -s and then do a
manual reboot. 2. Need to power
cycle the switch. The switch functions
properly after power cycle with
normal access to the telnet session.
Firmware downgrade from FOS v6.2.0 to v6.1.0 sometimes causes
an unresponsive console, which requires a switch power cycle to re-
cover.
Fixed in Fabric OS 6.3.0
Rekeyed LUNs are in "Not Ready (Getting key from archive)" state
when the key vault goes down and does not recover.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Add members with the
Add other
button.
Web Tools Zone Admin
Add member
button is always disabled.
Fixed in Fabric OS 6.3.0
In non-VF mode on DC SAN Director, after removing other filters (EE
and F_Port TT) and enabling Fabric mode TopTalkers, the flow values
are not reliable.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Mannually block and unblock an
E_Port to rebuild the fabric.
HA Failover on DC SAN Director caused: Need to reboot the system
for recovery, reason: System bring up timed out.
Fixed in Fabric OS 6.3.0
In Access gateway mode,Port swap and Enable/Disable NPIV option
is enabled in Web Tools.
Fixed in Fabric OS 6.3.0
As DCFM polling LUNs, the memory usage for weblinker is increased.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Logout all the devices registered their
HBA info and log them in after the
fabric is stable.
FDMI: fdmid crashes when a brocade HBA with virtual ports is connec-
ted to a 4/256 SAN Director.
Fixed in Fabric OS 6.3.0
Brocade 8000 firmware download hot code load shows no identifier
in the HTML page.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Activate the same PDCM Matrix from
WebTools, with
Active=Save Mode
checked from
Edit CUP Port
Connectivity Configuration
window.
Unable to activate a new PDCM Matrix with Webtools.
Fixed in Fabric OS 6.3.0
VCM don
t have GUI capability to change SNMP read community
configuration.
Fixed in Fabric OS 6.3.0
8/80 SAN Switch: Removing any power supply FRU causes fans to
speed up for a short period (which is not expected).
HP StorageWorks Fabric OS 6.3.0 release notes