HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 62

FOS-FVT- If a Read is Sent Busy Status and the Subsequent Seek is also

Page 62 highlights

Detected termination of management server daemon during stress testing on DC SAN Director with 8 logical switches. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Wait for system to stabilize after executing bladedisable and before issuing hafailover or disable MS platform services while performing stress testing. FOS-FVT- If a Read is Sent Busy Status and the Subsequent Seek is also Fixed in Fabric OS 6.3.0 Sent Busy, Mis-Compares To the Host. Downloading config file between switches causes license lost. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Do the following to back up licenses: 1. Execute licenseshow command save the licenses into a file outside the switch. 2. Then perform configdownload. 3. Add the licenses saved in step one. Inconsistent display of urouteshow trying to map to invalid FCR user port while topologyshow is not showing those routes. Fixed in Fabric OS 6.3.0 If user account on RADIUS server is set up with only Chassis level role as primary, but it is not on the LF role list, the user cannot login. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Specify LF role list in the RADIUS server for the account. Missing Pause and Resume for EX port having MiI10K Edge Fabric in Fixed in Fabric OS 6.3.0 239 Domain - works for domain 209-238. While performing security related fabric wide operations if fabric becomes unstable, user might observe verify on standby. Fixed in Fabric OS 6.3.0 Workaround prior to code change: System will recover. Setting the E-Net portname on the Primary CP does not get copied over to the standby CP. Fixed in Fabric OS 6.3.0 NPIV devices on a single port are spread across effective and McDATA default configurations, only devices from default configuration can establish communication. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Do not overlap effective and default zones on the same NPIV port, following best practices guidelines. Access Gateways connected to EOSc in a mixed fabric (FOS and EOS) are not shown in DCFM. Fixed in Fabric OS 6.3.0 Not able to add EE monitor on port 1 after firmwareupgrade from 6.1.0c to 6.2.0 on 400 multiprotocol router. Fixed in Fabric OS 6.3.0 Nsinfo.htm returns NPIV info as Physical if non-VF switch is connected Fixed in Fabric OS 6.3.0 to VF enabled platform. CP experienced a kenel panic "Oops: kernel access of bad area, sig: Fixed in Fabric OS 6.3.0 11 [#1]". 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Wait for system to stabilize after
executing bladedisable and before
issuing hafailover or disable MS
platform services while performing
stress testing.
Detected termination of management server daemon during stress
testing on DC SAN Director with 8 logical switches.
Fixed in Fabric OS 6.3.0
FOS-FVT- If a Read is Sent Busy Status and the Subsequent Seek is also
Sent Busy, Mis-Compares To the Host.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do the following to back up licenses:
1. Execute licenseshow command
save the licenses into a file outside the
switch. 2. Then perform
configdownload. 3. Add the licenses
saved in step one.
Downloading config file between switches causes license lost.
Fixed in Fabric OS 6.3.0
Inconsistent display of urouteshow trying to map to invalid FCR user
port while topologyshow is not showing those routes.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Specify LF role list in the RADIUS
server for the account.
If user account on RADIUS server is set up with only Chassis level role
as primary, but it is not on the LF role list, the user cannot login.
Fixed in Fabric OS 6.3.0
Missing Pause and Resume for EX port having MiI10K Edge Fabric in
239 Domain - works for domain 209-238.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
System will recover.
While performing security related fabric wide operations if fabric be-
comes unstable, user might observe verify on standby.
Fixed in Fabric OS 6.3.0
Setting the E-Net portname on the Primary CP does not get copied
over to the standby CP.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not overlap effective and default
zones on the same NPIV port,
following best practices guidelines.
NPIV devices on a single port are spread across effective and McDATA
default configurations, only devices from default configuration can
establish communication.
Fixed in Fabric OS 6.3.0
Access Gateways connected to EOSc in a mixed fabric (FOS and
EOS) are not shown in DCFM.
Fixed in Fabric OS 6.3.0
Not able to add EE monitor on port 1 after firmwareupgrade from
6.1.0c to 6.2.0 on 400 multiprotocol router.
Fixed in Fabric OS 6.3.0
Nsinfo.htm returns NPIV info as Physical if non-VF switch is connected
to VF enabled platform.
Fixed in Fabric OS 6.3.0
CP experienced a kenel panic "Oops: kernel access of bad area, sig:
11 [#1]".
62