HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 59

A LUN gets stuck in the Internal EE LUN State: Read Only Internal, PRESS_FAIL : Cmd 0x932b6000

Page 59 highlights

Issues with Brocade MIB objects with ifSpeed returns wrong value, ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards, Fixed in Fabric OS 6.3.0 snmpSilentDrops, snmpProxyDrops needs to be documented. After cfgdefault and migration from Interopmode 0 to Interopmode 2, all switches are setting idid bit in ESA, when idid is not enabled. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Fabric can be merged by disabling the switches and setting idid mode in the switch configurations, then bringing the switches online. This option is applicable only in the event the user wishes to merge the switch to a fabric that also has idid set. Syshutdown: execution of command in current build yields only "this is a unknown system" string on session consoles. Cannot use "fwconfigure" to view the information on internal F/FL ports (Copper). Internal routes are not being configured. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Port state mismatch on internal copper ports on Embedded platforms Fixed in Fabric OS 6.3.0 between switchshow and portcfgshow's PersistentDisable flag. The Distribute Policy option is missing from the SCC and DCC tabs in Fixed in Fabric OS 6.3.0 web mgmt. Supportshow cli command output should complete without having to Fixed in Fabric OS 6.3.0 hit CR several times. FVT: lun state never changed from write metadata to enable after GE Fixed in Fabric OS 6.3.0 port enable. Urouteshow will lag for several seconds at a time while displaying the Fixed in Fabric OS 6.3.0 route info. A LUN gets stuck in the Internal EE LUN State: Read Only (Internal metadata key is in RO state). Fixed in Fabric OS 6.3.0 After changing to non-FCS primary policy, web client can still activate Fixed in Fabric OS 6.3.0 ACL policy. Web Tools shows high CPU usage (~80%) when port configuration operation is performed in DCX. Fixed in Fabric OS 6.3.0 FICON fcip block count mismatch on read emulation. Fixed in Fabric OS 6.3.0 Unable to enable FMS Mode using webtools on a DC04 SAN Director Fixed in Fabric OS 6.3.0 with a 48 port blade. Node descriptors are not shown for M-EOS switch in DCFM when using Fixed in Fabric OS 6.3.0 FOS switch as the seed switch. Get error CHASSIS, ERROR, SYS, FPGA error, DECRYPT_DECOMPRESS_FAIL : Cmd 0x932b6000, Myxid 0x6b3, PI/PT 0x41d00/0x41acc, Lun 0, PIOxid 0x131 PTRxid and the tape drive is brought offline when labling a tape using TSM application. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Erase the media outside of the Encryption SAN Switch and then continue on with label. HP StorageWorks Fabric OS 6.3.0 release notes 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Fixed in Fabric OS 6.3.0
Issues with Brocade MIB objects with ifSpeed returns wrong value,
ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards,
snmpSilentDrops, snmpProxyDrops needs to be documented.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Fabric can be merged by disabling
the switches and setting idid mode in
the switch configurations, then
bringing the switches online. This
option is applicable only in the event
the user wishes to merge the switch
to a fabric that also has idid set.
After cfgdefault and migration from Interopmode 0 to Interopmode 2,
all switches are setting idid bit in ESA, when idid is not enabled.
Fixed in Fabric OS 6.3.0
Syshutdown: execution of command in current build yields only "this
is a unknown system" string on session consoles.
Fixed in Fabric OS 6.3.0
Cannot use
fwconfigure
to view the information on internal F/FL
ports (Copper).
Fixed in Fabric OS 6.3.0
Internal routes are not being configured.
Fixed in Fabric OS 6.3.0
Port state mismatch on internal copper ports on Embedded platforms
between switchshow and portcfgshow's PersistentDisable flag.
Fixed in Fabric OS 6.3.0
The Distribute Policy option is missing from the SCC and DCC tabs in
web mgmt.
Fixed in Fabric OS 6.3.0
Supportshow cli command output should complete without having to
hit CR several times.
Fixed in Fabric OS 6.3.0
FVT: lun state never changed from write metadata to enable after GE
port enable.
Fixed in Fabric OS 6.3.0
Urouteshow will lag for several seconds at a time while displaying the
route info.
Fixed in Fabric OS 6.3.0
A LUN gets stuck in the Internal EE LUN State: Read Only (Internal
metadata key is in RO state).
Fixed in Fabric OS 6.3.0
After changing to non-FCS primary policy, web client can still activate
ACL policy.
Fixed in Fabric OS 6.3.0
Web Tools shows high CPU usage (~80%) when port configuration
operation is performed in DCX.
Fixed in Fabric OS 6.3.0
FICON fcip block count mismatch on read emulation.
Fixed in Fabric OS 6.3.0
Unable to enable FMS Mode using webtools on a DC04 SAN Director
with a 48 port blade.
Fixed in Fabric OS 6.3.0
Node descriptors are not shown for M-EOS switch in DCFM when using
FOS switch as the seed switch.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Erase the media outside of the
Encryption SAN Switch and then
continue on with label.
Get error CHASSIS, ERROR, SYS, FPGA error, DECRYPT_DECOM-
PRESS_FAIL : Cmd 0x932b6000, Myxid 0x6b3, PI/PT
0x41d00/0x41acc, Lun 0, PIOxid 0x131 PTRxid and the tape drive
is brought offline when labling a tape using TSM application.
HP StorageWorks Fabric OS 6.3.0 release notes
59