A LUN gets stuck in the Internal EE LUN State: Read Only Internal, PRESS_FAIL : Cmd 0x932b6000
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Issues with Brocade MIB objects with ifSpeed returns wrong value, ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards, Fixed in Fabric OS 6.3.0 snmpSilentDrops, snmpProxyDrops needs to be documented. After cfgdefault and migration from Interopmode 0 to Interopmode 2, all switches are setting idid bit in ESA, when idid is not enabled. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Fabric can be merged by disabling the switches and setting idid mode in the switch configurations, then bringing the switches online. This option is applicable only in the event the user wishes to merge the switch to a fabric that also has idid set. Syshutdown: execution of command in current build yields only "this is a unknown system" string on session consoles. Cannot use "fwconfigure" to view the information on internal F/FL ports (Copper). Internal routes are not being configured. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Port state mismatch on internal copper ports on Embedded platforms Fixed in Fabric OS 6.3.0 between switchshow and portcfgshow's PersistentDisable flag. The Distribute Policy option is missing from the SCC and DCC tabs in Fixed in Fabric OS 6.3.0 web mgmt. Supportshow cli command output should complete without having to Fixed in Fabric OS 6.3.0 hit CR several times. FVT: lun state never changed from write metadata to enable after GE Fixed in Fabric OS 6.3.0 port enable. Urouteshow will lag for several seconds at a time while displaying the Fixed in Fabric OS 6.3.0 route info. A LUN gets stuck in the Internal EE LUN State: Read Only (Internal metadata key is in RO state). Fixed in Fabric OS 6.3.0 After changing to non-FCS primary policy, web client can still activate Fixed in Fabric OS 6.3.0 ACL policy. Web Tools shows high CPU usage (~80%) when port configuration operation is performed in DCX. Fixed in Fabric OS 6.3.0 FICON fcip block count mismatch on read emulation. Fixed in Fabric OS 6.3.0 Unable to enable FMS Mode using webtools on a DC04 SAN Director Fixed in Fabric OS 6.3.0 with a 48 port blade. Node descriptors are not shown for M-EOS switch in DCFM when using Fixed in Fabric OS 6.3.0 FOS switch as the seed switch. Get error CHASSIS, ERROR, SYS, FPGA error, DECRYPT_DECOMPRESS_FAIL : Cmd 0x932b6000, Myxid 0x6b3, PI/PT 0x41d00/0x41acc, Lun 0, PIOxid 0x131 PTRxid and the tape drive is brought offline when labling a tape using TSM application. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Erase the media outside of the Encryption SAN Switch and then continue on with label. HP StorageWorks Fabric OS 6.3.0 release notes 59