HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, - Page 58
SCSI Read/Write on a LUN Per port graph., Close and re-open Fabric Watch.
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
The SFP parameters are not returning for the ports which are under the logical switches other than the default logical switch. ptsupportshow -all does not function properly. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Workaround prior to code change: Specify the slot number for which the command is directed. For example, ptsupportshow 1 -all command to see all ports on blade 1. WEBLINKERFCGD core files after weekend SAK/IRNDUP run on DC04 Fixed in Fabric OS 6.3.0 SAN Director. Applications cannot distinguish between multiprotocol router blade and Core blades on DC SAN Director using SNMP. Need to add two Fixed in Fabric OS 6.3.0 new FRU classes: "coreblade" and "applicationblade" class. Switch panic in ficon enviormnet when blocking/unblocking E-Port due Fixed in Fabric OS 6.3.0 to RNID data count is incorrect. Switch Admin: when user moves to a different tab without applying changes, no warning is displayed. Fixed in Fabric OS 6.3.0 Performance Monitoring: Error message is shown when launching SCSI Read/Write on a LUN Per port graph. Fixed in Fabric OS 6.3.0 Enabled minimum FOS support for DWDM-SFP port media. Fixed in Fabric OS 6.3.0 Re-keys are getting stuck. Fixed in Fabric OS 6.3.0 DC SAN Director: configdownload: simple upload/download (switch enabled) complaining about FID 128 and will not download with Fixed in Fabric OS 6.3.0 switch enabled. Switch Admin: CEE: NPE is shown in error message when user applies a new FCoE login group (with Login management disabled.) Fixed in Fabric OS 6.3.0 Workaround prior to code change: User has to execute the CLI command fcoelogincfg before using Web Tools to create the login groups. pertperfshow does not display decimal data if overall throughput ex- Fixed in Fabric OS 6.3.0 ceeds 10Gbps. A switch restart causes random ICL E-Ports to come up "segmented." Fixed in Fabric OS 6.3.0 Workaround prior to code change: Port toggle when it gets segmented. When running FCoE traffic, debug_csock_read_header failures message displays. Fabric Watch: The FRU status does not auto-refresh after removal/insertion of the FRU. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Workaround prior to code change: Close and re-open Fabric Watch. FCoE frames from any SMAC are incorrectly passed to the FC side. Switchname mismatch between GUI display and CLI. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 58