Intel S5500WB12V Product Specification - Page 86
BIOS Detected, Integrated BMC Detected, Notes
View all Intel S5500WB12V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Intel® Light-Guided Diagnostics Intel® Server Board S5500WB TPS Color State Amber Solid on Off N/A System Status Fatal Not ready Description Fatal alarm - system has failed or shut down: BIOS Detected 1. DIMM failure when there is one DIMM present and no good memory is present.1 2. Run-time memory uncorrectable error in non-redundant mode.1 3. CPU configuration error (for instance, processor stepping mismatch). Integrated BMC Detected 1. CPU IERR signal asserted. 2. CPU 1 is missing. 3. CPU THERMTRIP. 4. No power good - power fault. 5. Power Unit Redundancy sensor - Insufficient resources offset (indicates not enough power supplies are present). AC power off Notes: 1. The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to provide the contribution to the system status LED. 2. Support for an upper, non-critical threshold limit is not provided in default SDR configuration. However if a user does enable this threshold in the SDR, then the system status LED should behave as described. 72 Revision 1.9 Intel order number E53971-008