Kenmore 9787 Use and Care Guide - Page 11
Kenmore 9787 - Elite HE3 7.0 cu. Ft. Gas Dryer Manual
View all Kenmore 9787 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Alternate installations for close clearances Determine r Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. vent path and most Select the route that will provide the straightest direct path outdoors. Plan the installation turns. to use the fewest number of elbows and When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90 ° turns possible. Determine vent length drying performance and elbows needed for best • B A A. Over-the-top installation (also available with one offset elbo_ B. Periscope installation • • NOTE: The following kits for close clearance alternate installations are available for purchase. For further information please call 1-800-4-MY-HOME ®(1-800-469-4663). • Over-the-Top Installation: Part Number 26-49900 • Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 26-49901 - Less than 5" (12.7 cm) mismatch Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm) mismatch Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will: • • Shorten the life of the dryer. Reduce performance, resulting in longer drying times and increased energy usage. The Vent system chart provides venting requirements that will help to achieve the best drying performance. Vent system chart NOTE: Side and bottom exhaust installations have a 90 ° turn inside the dryer. To determine maximum exhaust length, add one 90 ° turn to the chart. Number of 90 ° turns or elbows 0 Type of vent Box or Louvered hoods 64 ft (20 m) 36 ft (11 m) 54 ft (16.5 m) 31 ft (9.4 m) 44 ft (13.4 m) 27 ft (8.2 m) 35 ft (10.7 m) 25 ft (7.6 m) 27 ft (8.2 m) 23 ft (7 m) Angled hoods Rigid metal Flexible metal Rigid metal Flexible metal Rigid metal Flexible metal Rigid metal Flexible metal Rigid metal Flexible metal 58 ft (17.7 m) 28 ft (8.5 m) 48 ft (14.6 m) 23 ft (7 m) 38 ft (11.6 m) 19 ft (5.8 m) 29 ft (8.8 m) 17 ft (5.2 m) 21 ft (6.4 m) 15 ft (4.6 m) 1 2 3 4 11