Motorola WR850G User Guide - Page 72

Port Triggers, Outbound Protocol, Outbound Port Range, To Port Range

Page 72 highlights

Configuration Section 3 Port Triggers: (continued) For each port trigger, the following 5 items can be entered: (1) Outbound Protocol: This field specifies the Internet communication protocol that will be monitored on specified outbound ports. • Selecting TCP monitors the Transmission Control Protocol, an end-to-end protocol defining rules and procedures for data exchange between hosts. • Selecting UDP monitors the User Datagram Protocol, which is used in conjunction with the Internet Protocol (IP) to send data in the form of message units. This selection must be made for each port trigger. FACTORY DEFAULT: TCP (2) Outbound Port Range: These two fields ("Start" and "End") define a range of outbound destination ports that will be monitored as part of the port trigger. To monitor a single port, enter the same port number in both fields. This information must be entered for each port trigger. FACTORY DEFAULT: (blank) (3) Inbound Protocol: This field specifies the Internet communication protocol that will be monitored, for forwarding in response to the outbound trigger. Selections are TCP and UDP, as was the case when selecting the Outbound Protocol. This selection must be made for each port trigger. FACTORY DEFAULT: TCP (4) Inbound Port Range: These two fields ("Start" and "End") define a range of inbound destination ports on the WAN connection that will be monitored in response to the port trigger. To monitor communications from a single port, enter the same port number in both fields. This information must be entered for each port trigger. FACTORY DEFAULT: (blank) (5) To Port Range: These two fields ("Start" and "End") define a range of LAN ports to which communications will be forwarded, in response to the port (continued on next page)) WR850 3-39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

Configuration
Section 3
WR850
3-39
Port Triggers:
(continued)
For each port trigger, the following 5 items can be entered:
(1) Outbound Protocol
:
This field specifies the Internet communication protocol that will
be monitored on specified outbound ports.
Selecting
TCP
monitors the Transmission Control Protocol,
an end-to-end protocol defining rules and procedures for data
exchange between hosts.
Selecting
UDP
monitors the User Datagram Protocol, which
is used in conjunction with the Internet Protocol (IP) to send
data in the form of message units.
This selection must be made for each port trigger.
FACTORY DEFAULT:
TCP
(2) Outbound Port Range
:
These two fields (“Start” and “End”) define a range of outbound
destination ports that will be monitored as part of the port trigger. To
monitor a single port, enter the same port number in both fields.
This information must be entered for each port trigger.
FACTORY DEFAULT:
(blank)
(3) Inbound Protocol
:
This field specifies the Internet communication protocol that will be
monitored, for forwarding in response to the outbound trigger.
Selections are
TCP
and
UDP
, as was the case when selecting the
Outbound Protocol.
This selection must be made for each port trigger.
FACTORY DEFAULT:
TCP
(4) Inbound Port Range
:
These two fields (“Start” and “End”) define a range of inbound
destination ports on the WAN connection that will be monitored in
response to the port trigger.
To monitor communications from a
single port, enter the same port number in both fields.
This information must be entered for each port trigger.
FACTORY DEFAULT:
(blank)
(5) To Port Range
:
These two fields (“Start” and “End”) define a range of LAN ports to
which communications will be forwarded, in response to the port
(continued on next page))