Uniden BC250D English Owners Manual - Page 45

C 001, 0000 NFM, CTCSS 250.3, Bank 1, C 003, UNIDEN Group

Page 45 highlights

3. Rotate the VFO to select one type (1:CSQ, 2:TONE SQ, 3:TONE SEARCH) and press E. 4. To set Tone Lock mode, do the following first, then select 2:TONE SQ in step 3. 1) For Scan mode, select 2:SCAN OPTION / 1:CONVENTIONAL - select the channel number 3:TONE DATA - 1:CTCSS or 2:DCS by rotating the VFO and pressing E. With CTCSS or DCS, Tone Lock ON is set by pressing L/O. 2) For Search mode, select 1:SERVICE OPTION / :CHAIN SEARCH / 5:TONE DATA / 1:CTCSS or 2:DCS by rotating the VFO and pressing E. With CTCSS or DCS Tone Lock ON is set by pressing L/O. Note: • To set Tone Lock OFF for either Scan mode or Search mode, press E instead of pressing L/O on step 1) or 2) above. • CTCSS: Continuous Tone Coded Squelch System. • DCS: Digital Coded Squelch. • For example, the scanner shows the following displays. When Search mode and Tone Search are selected, the display shows the frequency and tone data alternately. C 001 512.0000 NFM CTCSS 250.3 Bank 1 Tone SQ ON, CTCSS 250.3 Hz setting C 001 512.0000 NFM DCS 025 Bank 1 Tone SQ ON, DCS 025 setting C 001 512.0000 NFM Bank 1 Tone SQ ON, CTCSS & DCS non-setting C 003 512.0000 NFM CTCSS 250.3 UNIDEN Group A Tone Search, CTCSS 250.3 Hz detecting C 003 512.0000 NFM DCS 025 UNIDEN Group A Tone Search, DCS 025 detecting C 003 512.0000 NFM UNIDEN Group A Tone Search, no signal received • If the Delay feature has been set while in Tone Search mode, it resumes scanning after a 2 second delay. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

41
3.
Rotate the
VFO
to select one type (
1:CSQ
,
2:TONE
SQ
,
3:TONE SEARCH
) and press
E
.
4.
To set Tone Lock mode, do the following first, then select
2:TONE SQ
in step 3.
1) For Scan mode, select
2:SCAN OPTION
/
1:CONVENTIONAL
- select the channel number -
3:TONE DATA
-
1:CTCSS
or
2:DCS
by rotating
the
VFO
and pressing
E
. With CTCSS or DCS, Tone
Lock ON is set by pressing
L/O
.
2) For Search mode, select
1:SERVICE OPTION
/
:CHAIN SEARCH
/
5:TONE DATA
/
1:CTCSS
or
2:DCS
by rotating the
VFO
and pressing
E
. With
CTCSS
or
DCS
Tone Lock ON is set by pressing
L/O
.
Note
:
To set Tone Lock OFF for either Scan mode or
Search mode, press
E
instead of pressing
L/O
on
step 1) or 2) above.
CTCSS: Continuous Tone Coded Squelch
System.
DCS: Digital Coded Squelch.
For example, the scanner shows the following
displays. When Search mode and Tone Search
are selected, the display shows the frequency and
tone data alternately.
If the Delay feature has been set while in Tone
Search mode, it resumes scanning after a 2 second
delay.
C 001
512.0000 NFM
CTCSS 250.3
Bank 1
C 001
512.0000
NFM
DCS
025
Bank 1
C 001
512.0000
NFM
Bank 1
C 003
512.0000 NFM
CTCSS 250.3
UNIDEN Group A
C 003
512.0000 NFM
DCS
025
UNIDEN Group A
C 003
512.0000 NFM
UNIDEN Group A
Tone SQ ON,
CTCSS 250.3 Hz
setting
Tone Search,
CTCSS 250.3 Hz
detecting
Tone Search,
DCS 025 detecting
Tone Search,
no signal received
Tone SQ ON,
DCS 025 setting
Tone SQ ON,
CTCSS & DCS
non-setting