Whirlpool WFC8090GX Installation Instructions - Page 28
Optional External Ground, for 3-Wire Connection, Connect remaining wires, Prepare to connect neutral
View all Whirlpool WFC8090GX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Optional External Ground for 3-Wire Connection IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. 1. Prepare to connect neutral wire A B 3. Connect remaining wires Remove center terminal block screw (A) and green external ground conductor screw (B). 2. Connect neutral wire A C Place ends of remaining wires under outer terminal block screws. Tighten screws and tighten strain relief. 4. Connect external ground wire DB Connect neutral wire (white or center) (C) of power supply cord or cable under center terminal block screw (A). Tighten screw. Connect a separate copper ground wire (D) under the green external ground conductor screw (B) to an adequate ground. Finally, install terminal block cover and secure with the three screws. Now, go to "Route Drain Hose." 28