A SYSTEM SPECIFICATIONS Table 10 System Specifications for the CoreBuilder 9400 Specifications Physical Dimensions 13.3 cm (H) x 44 cm (W) x 41.9 cm (D) 5.22 inches (H) x 17.32 inches (W) x 16.50 inches (D) Weight: 14.5 kg (32 lbs) Environmental Requirements Operating Temperature Operating Humidity Storage Temperature Storage Humidity Safety Agency Certifications Designed to Comply with... 0 to 50 °C (32 to 122 °F) 10 to 95% relative humidity, noncondensing -20 to 85 °C (-4 to 185 °F) 95% maximum relative humidity, noncondensing UL 1950, CSA 22.2 No. 950, TUV EN60950 UK General Approval Statement The CoreBuilder 9400 is manufactured to the international Safety Standard EN60950 and is approved in the UK under the General Approval Number NS/G/12345/J/100003 for indirect connection to the public telecommunication network. IEC 950 Electromagnetic Emissions Heat Dissipation Meets FCC part 15, Class A limits, and CISPR22 Class A limits Complies with EMC Council Directive 89/336/EEC, Class A limits 327 watts maximum (1116 BTU/hour maximum) Power Supply Receptacles AC Line Frequency Input Voltage Options Current Rating 15 ampere service receptacles, type N5/15 or NEMA 5-15R (United States and Canada only) 47 to 63 Hz 100 to 240 VAC 2.7 amperes at 120 volts

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

A
S
YSTEM
S
PECIFICATIONS
Table 10
System Specifications for the CoreBuilder 9400
Specifications
Physical Dimensions
13.3 cm (H) x 44 cm (W) x 41.9 cm (D)
5.22 inches (H) x 17.32 inches (W) x 16.50 inches (D)
Weight: 14.5 kg (32 lbs)
Environmental Requirements
Operating Temperature
0 to 50 °C (32 to 122 °F)
Operating Humidity
10 to 95% relative humidity, noncondensing
Storage Temperature
–20 to 85 °C (–4 to 185 °F)
Storage Humidity
95% maximum relative humidity, noncondensing
Safety
Agency Certifications
UL 1950, CSA 22.2 No. 950, TUV EN60950
UK General Approval Statement
The CoreBuilder 9400 is manufactured to the international Safety Standard EN60950 and is
approved in the UK under the General Approval Number NS/G/12345/J/100003 for indirect
connection to the public telecommunication network.
Designed to Comply with...
IEC 950
Electromagnetic Emissions
Meets FCC part 15, Class A limits, and CISPR22 Class A limits
Complies with EMC Council Directive 89/336/EEC, Class A limits
Heat Dissipation
327 watts maximum (1116 BTU/hour maximum)
Power Supply
Receptacles
15 ampere service receptacles, type N5/15 or NEMA 5-15R (United States and Canada only)
AC Line Frequency
47 to 63 Hz
Input Voltage Options
100 to 240 VAC
Current Rating
2.7 amperes at 120 volts