Adaptec 44300 User Guide - Page 94
Environmental Specifications, DC Power Requirements, Current Requirements - 000
View all Adaptec 44300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Appendix G: Technical Specifications ● 94 Environmental Specifications Ambient temperature without forced airflow Ambient temperature with forced airflow of atleast 200 CFM Relative humidity Altitude 0°C to 40° C 0°C to 55° C 10% to 90%, noncondensing up to 3,000 meters Note: Forced airflow is recommended, but not required. DC Power Requirements PCI, PCI-X, PCIe PCI, PCIX PCIe Ripple and noise DC Voltage DC Voltage 50mV peak-to-peak (max) 5V ±5%, 3.3V ± 10% 3.3V ± 10% Current Requirements Adaptec Model ASC-58300 ASC-48300 ASC-44300 AAR-1430SA AAR-1420SA AAR-1220SA AAR-1225SA Maximum Current (A) 0.56A 1.322A .445A 1.5A 1.5A 1.5A 1.5A
Appendix G: Technical Specifications
●
94
Environmental Specifications
Note:
Forced airflow is recommended, but not required.
DC Power Requirements
Current Requirements
Ambient temperature without forced
airflow
0°C to 40°
C
Ambient temperature with forced
airflow of atleast 200 CFM
0°C to 55°
C
Relative humidity
10% to 90%, noncondensing
Altitude
up to 3,000 meters
PCI, PCI-X, PCIe
Ripple and noise
50mV peak-to-peak (max)
PCI, PCIX
DC Voltage
5V ±5%, 3.3V ± 10%
PCIe
DC Voltage
3.3V ± 10%
Adaptec Model
Maximum Current (A)
ASC-58300
0.56A
ASC-48300
1.322A
ASC-44300
.445A
AAR-1430SA
1.5A
AAR-1420SA
1.5A
AAR-1220SA
1.5A
AAR-1225SA
1.5A