Cleaning the Scanner Window
View all Brother International HL 5030 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
HL-5030/5040/5050/5070N SERVICE MANUAL 4) Clean the primary corona wire inside the drum unit by gently sliding the blue tab from right to left several times. Return the tab to the home position before re-install the drum unit assembly. Home position Fig. 5-25 ! CAUTION: Make sure that the blue tab on the drum unit is returned to the home position (▲ mark position) before re-installing the drum unit into the printer, or printed pages may have vertical stripes. 5) Re-install the drum unit into the printer. 6) Close the front cover. 3.3 Cleaning the Scanner Window When replacing the drum unit or toner cartridge with a new one, be sure to clean the scanner window. 1) Turn off the power switch and unplug the power cord. 2) Press the cover release button, and then open the front cover. 3) Pull the drum unit assembly out of the printer. ! CAUTION: It is recommended to place the drum unit assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner. 4) Gently wipe the scanner window with a soft dry cloth. Fig. 5-26 5) Re-install the drum unit assembly into the printer. Close the front cover. 5-15