Canon DP-V3120 Video Display Operation Guide - Page 10

Performing calibrations, Select [Start].

Page 10 highlights

Operating the Video Display Performing calibrations ( 37) 10 You can perform calibration using an external sensor, without using a computer. The supported external sensors are Konika Minolta Display Color Analyzers CA-310 and CA-210. Be sure to also read the instruction manual of the CA-310 and CA-210. The video display can perform measurement or calibration of the display using the DP-V Color Adjustment software. Refer to the Canon website for the DP-V Color Adjustment. 1 Connect the display color analyzer to the USB port of the main unit. 2 Select [Adjustment] [Picture Mode] [User 1-7]. 3 Select [Adjustment] [Detail Settings] [Calibration]. • Set each target value. 4 Select [Start]. • Please follow the information indicated on the screen. 5 Initialize the sensor. • Set the mode dial of the Universal Measuring Probe to [0-CAL]. • Press the jog dial of the video display, select [OK], and execute initialization. 6 Place the universal measuring probe pointing at the center of the video display. • Set the mode dial of the universal measuring probe to [MEAS] and place the probe as shown below according to the displayed content. Press the jog dial of the video display, select [OK], and execute calibration. For the DP-V2411 Konica Minolta Universal Measuring Probe CA-310 support: CA-PU32, CA-PU35 CA-210 support: CA-PU12, CA-PU15 Konica Minolta Display Color Analyzer CA-310, CA-210 7 Finish calibration. • When the message [Calibration is completed.] is displayed, press the jog dial and select [OK]. • If the message [Calibration error.] is displayed. Calibration has been terminated due to an error. The main unit returns to the state before calibration. ( 113) • To cancel calibration Press the jog dial during calibration and select [Cancel]. The main unit returns to the state before calibration.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Operating the Video Display
10
Performing calibrations (
37)
You can perform calibration using an external sensor, without using a computer.
The supported external sensors are Konika Minolta Display Color Analyzers CA-310 and CA-210. Be sure to also read
the instruction manual of the CA-310 and CA-210.
The video display can perform measurement or calibration of the display using the DP-V Color Adjustment software.
Refer to the Canon website for the DP-V Color Adjustment.
1 Connect the display color analyzer to the USB port of the main unit.
2 Select
[Adjustment]
[Picture Mode]
[User 1–7].
3 Select
[Adjustment]
[Detail Settings]
[Calibration].
• Set each target value.
4 Select [Start].
• Please follow the information indicated on the screen.
5 Initialize the sensor.
• Set the mode dial of the Universal Measuring Probe to [0-CAL].
• Press the jog dial of the video display, select [OK], and execute initialization.
6 Place the universal measuring probe pointing at the center of the video display.
• Set the mode dial of the universal measuring probe to [MEAS] and place the probe as shown below according to
the displayed content. Press the jog dial of the video display, select [OK], and execute calibration.
Konica Minolta Universal Measuring Probe
CA-310 support: CA-PU32, CA-PU35
CA-210 support: CA-PU12, CA-PU15
Konica Minolta
Display Color Analyzer CA-310, CA-210
For the DP-V2411
7 Finish calibration.
• When the message [Calibration is completed.] is displayed, press the jog dial and select [OK].
• If the message [Calibration error.] is displayed.
Calibration has been terminated due to an error. The main unit returns to the state before calibration. (
113)
• To cancel calibration
Press the jog dial during calibration and select [Cancel]. The main unit returns to the state before calibration.