Canon DP-V3120 Video Display Operation Guide - Page 67

Automatic, When [Gamma/EOTF]

Page 67 highlights

OSD Menu Sub Menu Display Type Select Line Scale Reference Line Reference Level All Line 1 to 2160 Automatic IRE SMPTE ST 2084 (PQ) Hybrid Log-Gamma Canon Log Canon Log 2 Canon Log 3 S-Log2 S-Log3 ARRI (Rec2100-PQ- 1K-100) ARRI (Rec2100-HLG- 1K-200) 4 to 1023 Automatic Manual Setting Options (Bold: factory default) Sets the display type. [Line]: The data for one line is displayed. 67 Selects the line to be displayed when [Line] is selected. Sets the scale of the wave form monitor. [Automatic]: Sets in accordance with the [Gamma/EOTF] and [Color Range] settings. • When [SMPTE ST 2084 (PQ)], [Canon Log], [Canon Log 2], or [Canon Log 3] is set (including [Automatic]): When [Gamma/EOTF] [SMPTE ST 2084 (PQ)], the item is displayed in accordance with the [Color Range] settings ([Limited 2] is set to [Limited] and [SDI Full (4-1019)] is set to [Full]). A guide is displayed at the specified position. [Reference Line] is not displayed when [1023] is selected. Sets the range of the reference level. Tints the outside of the range of the reference level. In the case of [Gamma/EOTF] corresponding to the HDR range, parts that exceed the HDR range are tinted. When [Color Range] [Limited], outside the limited range is tinted. Reference Level High Reference Level Low Color Y Cb Cr R G B Reference Level High Reference Level Low [Automatic]: Sets in accordance with the [Gamma/EOTF] and [Color Range] settings. 468 to 1023 Sets the reference display level (high). [Reference Level High] is not displayed when [1023] is selected. 0 to 468 Sets the reference display level (low). [Reference Level Low] is not displayed when [0] is selected. Sets the signals to be displayed and the color of signals exceeding the reference level. White Red Green Blue Yellow Cyan Magenta [Y], [Cb], [Cr], [R], [G], [B]: Selects the color of the selected signal. Default value of each signal is shown below. Y (White), Cb (White), Cr (White), R (Red), G (Green), B (Blue) [Reference Level High], [Reference Level Low]: Selects the color of the signal of the selected reference level. Default value of each reference level is shown below. Reference Level High (Magenta), Reference Level Low (Cyan)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

OSD Menu
67
Sub Menu
Setting Options (Bold: factory default)
Display Type
All
Line
Sets the display type.
[Line]: The data for one line is displayed.
Select Line
1
to 2160
Selects the line to be displayed when [Line] is selected.
Scale
Automatic
IRE
SMPTE ST 2084 (PQ)
Hybrid Log-Gamma
Canon Log
Canon Log 2
Canon Log 3
S-Log2
S-Log3
ARRI (Rec2100-PQ-
1K-100)
ARRI (Rec2100-HLG-
1K-200)
Sets the scale of the wave form monitor.
[Automatic]: Sets in accordance with the [Gamma/EOTF] and [Color
Range] settings.
• When [SMPTE ST 2084 (PQ)], [Canon Log], [Canon Log 2], or [Canon Log 3] is
set (including [Automatic]):
When [Gamma/EOTF]
[SMPTE ST 2084 (PQ)], the item is displayed in
accordance with the [Color Range] settings ([Limited 2] is set to [Limited] and [SDI
Full (4-1019)] is set to [Full]).
Reference Line
4 to
1023
A guide is displayed at the specified position. [Reference Line] is not
displayed when [1023] is selected.
Reference Level
Automatic
Manual
Sets the range of the reference level. Tints the outside of the range of the
reference level.
In the case of [Gamma/EOTF] corresponding to the HDR range, parts that
exceed the HDR range are tinted.
When [Color Range]
[Limited], outside the limited range is tinted.
[Automatic]: Sets in accordance with the [Gamma/EOTF] and [Color
Range] settings.
Reference Level
High
468 to 1023
Sets the reference display level (high). [Reference Level High] is not
displayed when [1023] is selected.
Reference Level
Low
0 to 468
Sets the reference display level (low). [Reference Level Low] is not
displayed when [0] is selected.
Color
Sets the signals to be displayed and the color of signals exceeding the reference level.
Y
White
Red
Green
Blue
Yellow
Cyan
Magenta
[Y], [Cb], [Cr], [R], [G], [B]: Selects the color of the selected signal.
Default value of each signal is shown below.
Y (White), Cb (White), Cr (White), R (Red), G (Green), B (Blue)
[Reference Level High], [Reference Level Low]: Selects the color of the
signal of the selected reference level.
Default value of each reference level is shown below.
Reference Level High (Magenta), Reference Level Low (Cyan)
Cb
Cr
R
G
B
Reference Level
High
Reference Level
Low