Canon SX50 Realis Command Codes - Page 32

Commands, SHARP, Function, Parameter, Response, Description, Example

Page 32 highlights

Commands SHARP Function Sharpness setting Mode Control Setting Reference Parameter Setting value (-4 to 4) The RANGE command can be used to obtain the parameter range that can be set at that time. Number Response An 'i:OK' is returned after setting is successful. Description This sets the screen sharpness. (1) This command is identical to the Sharpness function in the Image adj. menu. (2) This sets the currently selected input signal and image mode. (3) The GET command can be used to retrieve the current sharpness. Example Setting > SHARP=3 < i:OK This sets the sharpness to 3. Reference > GET SHARP or ?SHARP < g:SHARP=3 This retrieves the sharpness. Obtain settable parameter range (Min, Max) > RANGE SHARP < r:SHARP=N,-4,4 *Commands are indicated by ">", and responses are indicated by "

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

e
Commands
SHARP
Mode
Control
Setting
Referenc
Function
Sharpness setting
Parameter
Setting value (–4 to 4)
Number
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK' is returned after setting is successful.
Description
This sets the screen sharpness.
(1)
This command is identical to the Sharpness function in the Image adj. menu.
(2)
This sets the currently selected input signal and image mode.
(3)
The GET command can be used to retrieve the current sharpness.
Example
Setting
> SHARP=3
This sets the sharpness to 3.
< i:OK
Reference
> GET SHARP or ?SHARP
This retrieves the sharpness.
< g:SHARP=3
Obtain settable parameter range (Min, Max)
> RANGE SHARP
< r:SHARP=N,-4,4
*Commands are indicated by “>”, and responses are indicated by “<”.
Supported Command States
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1
A-RGB2
Comp
Video
S-Video
None
Remote
Local
×
×
×
If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.