Canon SX50 Realis Command Codes - Page 44

> GET HKS or ?HKS

Page 44 highlights

Commands VKS HKS Function Vertical/Horizontal keystone setting Mode Control Setting Reference Parameter Setting value The RANGE command can be used to obtain the parameter range that can be set at that time. Number Response An 'i:OK' is returned after setting is successful. Description This sets the vertical and horizontal keystones. (1) This command is identical to pressing the "KEYSTONE" button on the remote control or front panel. (2) The settable keystone range varies depending on the input signal, screen size, number of horizontal and vertical dots, and other factors. (3) Changing the vertical keystone value modifies the setting range of the horizontal keystone value, and changing the horizontal keystone value modifies the setting range of the vertical keystone value. (4) Use the "RANGE" command to obtain the range of settable values immediately before setting the vertical value and horizontal value. (5) The GET command can be used to obtain the current vertical/horizontal keystone value. Example Setting > VKS=-23 < i:OK This sets the vertical keystone to -23. > HKS=10 < i:OK This sets the horizontal keystone to 10. Reference > GET VKS or ?VKS < g:VKS=-23 This retrieves the vertical keystone. > GET HKS or ?HKS < g:HKS=-23 This retrieves the horizontal keystone. Obtain settable parameter range (Min, Max) > RANGE HKS < r:HKS=N,-30,30 *Commands are indicated by ">", and responses are indicated by "

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Commands
VKS
HKS
Mode
Control
Setting
Reference
Function
Vertical/Horizontal keystone setting
Parameter
Setting value
Number
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK' is returned after setting is successful.
Description
This sets the vertical and horizontal keystones.
(1)
This command is identical to pressing the “KEYSTONE” button on the remote control or front panel.
(2)
The settable keystone range varies depending on the input signal, screen size, number of horizontal and
vertical dots, and other factors.
(3)
Changing the vertical keystone value modifies the setting range of the horizontal keystone value, and
changing the horizontal keystone value modifies the setting range of the vertical keystone value.
(4)
Use the “RANGE” command to obtain the range of settable values immediately before setting the vertical
value and horizontal value.
(5)
The GET command can be used to obtain the current vertical/horizontal keystone value.
Example
Setting
> VKS=–23
This sets the vertical keystone to –23.
< i:OK
> HKS=10
This sets the horizontal keystone to 10.
< i:OK
Reference
> GET VKS or ?VKS
This retrieves the vertical keystone.
<
g:VKS=–23
> GET HKS or ?HKS
This retrieves the horizontal keystone.
<
g:HKS=–23
Obtain settable parameter range (Min, Max)
> RANGE HKS
< r:HKS=N,–30,30
*Commands are indicated by “>”, and responses are indicated by “<”.
Supported Command States
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1
A-RGB2
Comp
Video
S-Video
None
Remote
Local
×
×
×
×
If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.