Canon SX50 Realis Command Codes - Page 45

> Get Avol Or ?avol

Page 45 highlights

Commands AVOL Function Audio volume adjustment Mode Control Setting Reference Parameter Adjustment value (0 to 20) The RANGE command can be used to obtain the parameter range that can be set at that time. Response An 'i:OK' is returned after setting is successful. Number Description This adjusts the volume. (1) The final beep sound setting is retained even when the power is turned off. (2) This command is identical to pressing the "VOL" button on the remote control. (3) Although the volume setting can be made when set to "Mute", no sound will be made. (4) The GET command can be used to retrieve the current volume. Example Setting > AVOL=18 < i:OK This sets the volume to 18. Reference > GET AVOL or ?AVOL < g:AVOL=18 This retrieves the volume. Obtain settable parameter range (Min, Max) > RANGE AVOL < r:AVOL=N,0,20 *Commands are indicated by ">", and responses are indicated by "

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Commands
AVOL
Mode
Control
Setting
Reference
Function
Audio volume adjustment
Parameter
Adjustment value (0 to 20)
Number
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK' is returned after setting is successful.
Description
This adjusts the volume.
(1)
The final beep sound setting is retained even when the power is turned off.
(2)
This command is identical to pressing the “VOL” button on the remote control.
(3)
Although the volume setting can be made when set to “Mute”, no sound will be made.
(4)
The GET command can be used to retrieve the current volume.
Example
Setting
> AVOL=18
This sets the volume to 18.
< i:OK
Reference
> GET AVOL or ?AVOL
This retrieves the volume.
<
g:AVOL=18
Obtain settable parameter range (Min, Max)
> RANGE AVOL
< r:AVOL=N,0,20
*Commands are indicated by “>”, and responses are indicated by “<”.
Supported Command States
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1
A-RGB2
Comp
Video
S-Video
None
Remote
Local
×
×
×
If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.