Canon SX50 Realis Command Codes - Page 55

Commands, TERMINAL, Function, Parameter, Response, Description, Example

Page 55 highlights

Commands TERMINAL Function Terminal setting Parameter Parameter Meaning IN This sets to input. OUT This sets to output. Mode Control Setting Reference ID The RANGE command can be used to obtain the parameter range that can be set at that time. Response An 'i:OK 'is returned after setting is successful. Description This sets the input/output of the RGB-IN2/COMPONENT IN/RGB OUT terminals. (1) This command is identical to the Terminal command in the System settings menu. (2) The "OUT" (output) setting cannot be made when the "A-RGB2" or "COMP" input is selected! (3) The GET command can be used to retrieve the current terminal setting. Example Setting > TERMINAL=IN < i:OK This sets to input. Reference > GET TERMINAL or ?TERMINAL < g:TERMINAL=OUT This retrieves the terminal setting state. Obtain settable parameters > RANGE TERMINAL < r:TERMINAL=I,IN,OUT ※Commands are indicated by ">", and responses are indicated by "

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Commands
TERMINAL
Mode
Control
Setting
Reference
Function
Terminal setting
Parameter
ID
Parameter
Meaning
IN
This sets to input.
OUT
This sets to output.
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK 'is returned after setting is successful.
Description
This sets the input/output of the RGB-IN2/COMPONENT IN/RGB OUT terminals.
(1)
This command is identical to the Terminal command in the System settings menu.
(2)
The “OUT” (output) setting cannot be made when the “A-RGB2” or “COMP” input is selected!
(3)
The GET command can be used to retrieve the current terminal setting.
Example
Setting
> TERMINAL=IN
This sets to input.
< i:OK
Reference
> GET TERMINAL or ?TERMINAL
This retrieves the terminal setting state.
<
g:TERMINAL=OUT
Obtain settable parameters
> RANGE TERMINAL
< r:TERMINAL=I,IN,OUT
Commands are indicated by “>”, and responses are indicated by “<”
Supported Command States
Parameter
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1
A-RGB2
Comp
Video
S-Video
None
Remote
Local
IN
×
×
×
OUT
×
×
×
×
×
If a state is not supported, “INVALID_MODE”, “NOT_POWER_SUPPLIED” or “INVALID_SOURCE” is returned with the Err response.
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.