Canon imageFORMULA DR-6030C DR-6030C User Manual - Page 109
Cleaning the Sensor Glass, Shading Boards, and, the Rollers
View all Canon imageFORMULA DR-6030C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Cleaning the Sensor Glass, Shading Boards, and the Rollers If scanned images have extraneous marks, or if the scanned documents are dirty, then the sensor glass or rollers inside the scanner may be dirty. Clean them periodically. 1. Pressing the OPEN knob from both sides, raise the upper unit. Chapter 4 CAUTION The pickup roller is located in the middle of the upper unit. Do not hold the protrusion on the upper unit when you open it. Doing so may deform the pickup roller or cause a feeding error. Note The location of the sensor glass and various rollers are shown below. Platen Rollers Sensor Glasses Pickup Roller Feed Roller Rollers Retard Roller 2. Use a blower to keep the interior of the scanner free of dust and paper particles. Appendices 103