Spectrophotometer Unit Calibration white tile error., Spectrophotometer Unit eject guide not mounted.
View all Canon imagePROGRAF iPF6450 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
iPF6450 Spectrophotometer Unit Calibration white tile error. Spectrophotometer Unit Calibration white tile error. Cause The White Calibration Tile is not installed. The White Calibration Tile is dirty. Corrective Action Install the White Calibration Tile. (See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).") →User's Guide Remove, clean, and reinstall the White Calibration Tile. (See "Cleaning the Spectrophotometer Unit (option) Parts.") →P.54 The performance of part of the Spectrophotometer Sensor may be impaired. If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the Spectrophotometer Sensor. Contact your Canon dealer for more information on adjustment services. (See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).") →User's Guide Spectrophotometer Unit eject guide not mounted. Cause The Spectrophotometer Eject Guide is installed incorrectly, such as being installed askew, or not pushed in all the way. There is a foreign object on the Spectrophotometer Eject Guide. The performance of part of the Spectrophotometer Unit may be impaired. Corrective Action Make sure that the Spectrophotometer Eject Guide is loaded in the correct position, push it in all the way, and press the OK button. Remove the foreign object and press the OK button. Turn off the printer, wait a while, and then turn it on again. If the same message is displayed again, contact your Canon dealer for assistance. Error Message Spectrophotometer Unit Backing plate error. Cause The White/Black Backing Plate is not installed correctly. The White/Black Backing Plate is soiled. Corrective Action Remove and correctly attach the White/Black Backing Plate, and then press the OK button. (See "Switching the White/Black Backing Plate (Optional) Color.") →User's Guide Clean the White/Black Backing Plate and then press the OK button. (See "Cleaning the Spectrophotometer Unit (option) Parts.") →P.54 Messages regarding printing or adjustment Spectrophotometer up-down unit cover open. Cause Corrective Action The Up-down Unit Cover of the Spectrophotometer Unit is open. Close the Up-down Unit Cover and press the OK button. Spectrophotometer Unit cover open. Cause The Spectrophotometer Unit Cover of the Spectrophotometer Unit is open. Corrective Action Close the Spectrophotometer Unit Cover and press the OK button. Spectrophotometer read error. Cause Corrective Action The Spectrophotometer Sensor to be loaded into the Spectrophotometer Carriage is not installed correctly. Turn off the power, and reinstall by pushing the two connectors all the way into the Spectrophotometer Sensor. (See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).") →User's Guide The color measurement pattern was not printed correctly. Check the color measurement pattern. If the printing is faint, clean the printhead and perform the operation again. (See "Cleaning the Printhead.") →P.53 The color measurement pattern Pulling or lifting a printed color measurement pattern may cause the pattern to come out of alignment. 147 is out of alignment. Perform the operation again taking care not to touch the color measurement pattern. Execute Feed Priority to improve the printing position of the pattern for color measurement. Basic Guide