Cisco 3845 Message Guide - Page 57

no vlan, The port manager did not allocate the requested VLAN. The VLAN is probably being

Page 57 highlights

Chapter 2 Messages and Recovery Procedures PM Messages Error Message PM-4-ERR_RECOVER_VP: Attempting to recover from [chars] err-disable state on [chars], vlan [dec]. Explanation The port manager is trying to restart an error-disabled virtual port. The first [chars] is the error, the second [chars] is the virtual port, and [dec] is the VLAN ID. Recommended Action Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for similar reported problems. If you still need assistance, open a case with the TAC, or provide your Cisco technical support representative with your information. For more information about these online tools and about contacting Cisco, see the "Error Message Traceback Reports" section on page 1-5. Error Message PM-4-EXT_VLAN_INUSE: VLAN [dec] currently in use by [chars]. Explanation The port manager did not allocate the VLAN for external use because the VLAN is being used by another feature. [dec] is the VLAN that is being used, and [chars] is the feature that is using it. Recommended Action Reconfigure the feature (for example, the routed port) to use another internal VLAN or to request another available VLAN. Error Message PM-4-EXT_VLAN_NOTAVAIL: VLAN [dec] not available in Port Manager. Explanation The port manager did not allocate the requested VLAN. The VLAN is probably being used as an internal VLAN by other features. [dec] is the requested VLAN. Recommended Action Configure a different VLAN on the device. Error Message PM-4-INACTIVE: putting [chars] in inactive state because [chars]. Explanation The port is inactive because the port manager could not create a virtual port for the switch port and VLAN. The reason for this condition is specified in the error message. The first [chars] is the interface name, and the second [chars] is the reason. Recommended Action Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for similar reported problems. If you still need assistance, open a case with the TAC, or provide your Cisco technical support representative with your information. For more information about these online tools and about contacting Cisco, see the "Error Message Traceback Reports" section on page 1-5. Error Message PM-4-INT_FAILUP: [chars] failed to come up. No internal VLAN available. Explanation The port manager did not allocate an internal VLAN. The interface cannot be enabled. [chars] is the interface name. Recommended Action Remove the extended-range VLAN by using the no vlan vlan-id global configuration command to free up resources. OL-23408-01 Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide 2-43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

2-43
Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide
OL-23408-01
Chapter 2
Messages and Recovery Procedures
PM Messages
Error Message
PM-4-ERR_RECOVER_VP: Attempting to recover from [chars] err-disable
state on [chars], vlan [dec].
Explanation
The port manager is trying to restart an error-disabled virtual port. The first [chars] is
the error, the second [chars] is the virtual port, and [dec] is the VLAN ID.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still need assistance, open a case with the TAC, or provide
your Cisco technical support representative with your information. For more information about these
online tools and about contacting Cisco, see the
“Error Message Traceback Reports” section on
page 1-5
.
Error Message
PM-4-EXT_VLAN_INUSE: VLAN [dec] currently in use by [chars].
Explanation
The port manager did not allocate the VLAN for external use because the VLAN is
being used by another feature. [dec] is the VLAN that is being used, and [chars] is the feature that
is using it.
Recommended Action
Reconfigure the feature (for example, the routed port) to use another internal
VLAN or to request another available VLAN.
Error Message
PM-4-EXT_VLAN_NOTAVAIL: VLAN [dec] not available in Port Manager.
Explanation
The port manager did not allocate the requested VLAN. The VLAN is probably being
used as an internal VLAN by other features. [dec] is the requested VLAN.
Recommended Action
Configure a different VLAN on the device.
Error Message
PM-4-INACTIVE: putting [chars] in inactive state because [chars].
Explanation
The port is inactive because the port manager could not create a virtual port for the
switch port and VLAN. The reason for this condition is specified in the error message. The first
[chars] is the interface name, and the second [chars] is the reason.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still need assistance, open a case with the TAC, or provide
your Cisco technical support representative with your information. For more information about these
online tools and about contacting Cisco, see the
“Error Message Traceback Reports” section on
page 1-5
.
Error Message
PM-4-INT_FAILUP: [chars] failed to come up. No internal VLAN available.
Explanation
The port manager did not allocate an internal VLAN. The interface cannot be enabled.
[chars] is the interface name.
Recommended Action
Remove the extended-range VLAN by using the
no vlan
vlan-id
global
configuration command to free up resources.