Compaq ProLiant 400 ProLiant ML330 Setup and Installation Guide - Page 33

Removing the Access Panel

Page 33 highlights

3-4 Compaq ProLiant ML330 Setup and Installation Guide Removing the Access Panel To remove the access panel: WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching. CAUTION: Before removing the access panel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet. CAUTION: Do not operate the server with the access panel removed. This panel is an integral part of the cooling system and removing it while the system is running may adversely affect data integrity. 1. Remove front bezel. See "Removing the Front Bezel" earlier in this chapter. 2. Remove the screw located on the left side of the front chassis. 3. Slide the access panel forward, pull from the top of the access panel, then lift the panel from the chassis. 2 1 Figure 3-2. Removing the access panel NOTE: Turn the access panel over to locate the System Configuration Label. This label provides information about the system board on your ProLiant ML330. To replace the access panel, reverse the above procedure.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

3-4
Compaq ProLiant ML330 Setup and Installation Guide
Removing the Access Panel
To remove the access panel:
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the
internal system components to cool before touching.
CAUTION:
Before removing the access panel, make sure that the server is
powered down, all cables are disconnected from the back of the server, and the
power cord is disconnected from the grounded (earthed) AC outlet.
CAUTION:
Do not operate the server with the access panel removed. This panel
is an integral part of the cooling system and removing it while the system is
running may adversely affect data integrity.
1.
Remove front bezel. See “Removing the Front Bezel” earlier in this
chapter.
2.
Remove the screw
located on the left side of the front chassis.
3.
Slide the access panel
forward, pull from the top of the access panel,
then lift the panel from the chassis.
1
2
Figure 3-2.
Removing the access panel
NOTE:
Turn the access panel over to locate the System Configuration Label. This label
provides information about the system board on your ProLiant ML330.
To replace the access panel, reverse the above procedure.