Dell Force10 S4820T Installing the S4820T System - Page 33

Connecting the Stacking Ports (Optional), Important Port-Stacking Points to Know

Page 33 highlights

Connecting the Stacking Ports (Optional) Before you make your stacking port connections, rack-mount the systems or insert them into a cabinet. To connect the stacking ports, insert one end of the cable into a configured port and insert the other end of the cable into a similarly configured port of the adjacent system. NOTE: The maximum number of S4820T switches that can be stacked together is six. There are no unique stacking ports; you can configure the RJ-45 and QSFP+ ports to act as stacking ports. The RJ-45 ports are labeled 0-47. The QSFP+ ports are labeled 48 and 56 for the lower QSFP+ ports and 52 and 60 for the upper QSFP+ ports. NOTE: The S4820T system cannot be stacked with other S-Series systems. NOTE: Data Center Bridging is not supported on the S4820T if ports 0 - 47 are being used for stacking. Important Port-Stacking Points to Know When stacking the S4820T, keep the following in mind: • Data ports are configured as stacking ports in predefined stacking groups of 40G (four 10G ports or one 40G port). • When a stack-group number is assigned, the ports associated with that group are configured as stacking ports (Figure 4-7): • stack-group 0 = ports 0-3, stack-group 1 = ports 4-7, stack-group 2 = ports 8-11, and so on through stack-group 11 = ports 44-47. • stack-group 12 = port 48, stack-group 13 = port 52, stack-group 14 = port 56, stack-group 15 = port 60. • All the ports in a stack-group are placed in stacking mode. You cannot use the unused ports in that group as data ports. Figure 4-7. S4820T Stack-Group Assignment Stack Group 1 Stack Group 3 Stack Group 11 SG-13 SG-15 Stack Group 0 Stack Group 2 Stack Group 10 SG-12 SG-14 You can connect the systems while they are powered down or up. Stacking ports are bi-directional. The S4820T supports stacking in either a ring or a cascade topology (Figure 4-8). To provide redundant connectivity, Dell Force10 recommends using the ring topology when stacking S4820T systems. Installing the S4820T | 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Installing the S4820T
|
33
Connecting the Stacking Ports (Optional)
Before you make your stacking port connections, rack-mount the systems or insert them into a cabinet.
To connect the stacking ports, insert one end of the cable into a configured port and insert the other end of
the cable into a similarly configured port of the adjacent system.
NOTE:
The maximum number of S4820T switches that can be stacked together is six.
There are no unique stacking ports; you can configure the RJ-45 and QSFP+ ports to act as stacking
ports. The RJ-45 ports are labeled 0-47. The QSFP+ ports are labeled 48 and 56 for the lower QSFP+
ports and 52 and 60 for the upper QSFP+ ports.
NOTE:
The S4820T system cannot be stacked with other S-Series systems.
NOTE:
Data Center Bridging is not supported on the S4820T if ports 0 - 47 are being used for stacking.
Important Port-Stacking Points to Know
When stacking the S4820T, keep the following in mind:
Data ports are configured as stacking ports in predefined stacking groups of 40G (four 10G ports or one
40G port).
When a stack-group number is assigned, the ports associated with that group are configured as stacking
ports (
Figure 4-7
):
stack-group 0 = ports 0-3, stack-group 1 = ports 4-7, stack-group 2 = ports 8-11, and so on
through stack-group 11 = ports 44-47.
stack-group 12 = port 48, stack-group 13 = port 52, stack-group 14 = port 56, stack-group 15 =
port 60.
All the ports in a stack-group are placed in stacking mode. You cannot use the unused ports in that group
as data ports.
Figure 4-7.
S4820T Stack-Group Assignment
You can connect the systems while they are powered down or up. Stacking ports are bi-directional. The
S4820T supports stacking in either a ring or a cascade topology (
Figure 4-8
). To provide redundant
connectivity, Dell Force10 recommends using the ring topology when stacking S4820T systems.
Stack Group 0
Stack Group 1
Stack Group 2
Stack Group 3
Stack Group 11
Stack Group 10
SG-13
SG-15
SG-12 SG-14