Dell Force10 S4820T Installing the S4820T System - Page 35
Connect Three S4820T Systems, Two S4820T Systems Connected in a Ring, CAUTION
View all Dell Force10 S4820T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Figure 4-9. Two S4820T Systems Connected in a Ring Chassis 2 52 60 48 56 Chassis 1 52 60 48 56 Connect Three S4820T Systems To provide backup connectivity and increased data transfer between the systems, Dell Force10 recommends inserting an additional cable between the two units, in a second stacking port, as shown in Figure 4-10. CAUTION: To connect S4820T systems, use only Dell Force10 supported stacking cables. To connect three S4820T systems in a ring (Figure 4-10), starting with the S4820T at the bottom of the stack, follow these steps: NOTE: The port numbers in the following procedure are used as examples only. Step Task 1 Insert one end of the first cable into stack port 60 of chassis 1 (bottom). 2 Insert the other end of the cable into stack port 52 of chassis 2 (center). 3 Insert the second cable into stack port 60 of chassis 2 (center) and port 52 the chassis 3 (top). 4 Use the third cable to connect the top and bottom units by inserting one end of the cable into stack port 56 on chassis 1 (bottom) and the other end of the cable into stack port 60 on chassis 3 (top). Installing the S4820T | 35