Dell Latitude XPi Reference Guide - Page 48

address, value, failure

Page 48 highlights

Table 3-2. System Error Messages (Continued) Message Cause Action Memory address line failure at address, read value expecting value An installed memory module may be faulty or improperly seated. See "Troubleshooting Memory" found later in this chapter. Memory allocation error The software you are attempting to run is conflicting with the operating system, another application program, or a utility. Turn off the computer, wait 30 seconds, and then restart it. Try to run the program again. If the problem persists, contact the software company. Memory data line failure at address, read value expecting value An installed memory module may be faulty or improperly seated. See "Troubleshooting Memory" found later in this chapter. Memory double word logic failure at address, read value expecting value An installed memory module may be faulty or improperly seated. See "Troubleshooting Memory" found later in this chapter. Memory odd/ even logic failure at address, read value expecting value An installed memory module may be faulty or improperly seated. See "Troubleshooting Memory" found later in this chapter. Memory write/ read failure at address, read value expecting value An installed memory module may be faulty or improperly seated. See "Troubleshooting Memory" found later in this chapter. No boot device available The computer cannot find the diskette or hard-disk drive. If the diskette drive is your boot device, make sure there is a bootable diskette in the drive. If the hard-disk drive is your boot device, make sure the drive is installed, properly seated, and partitioned as a boot device. NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the online System User's Guide. 3-8 Dell Latitude XPi CD Reference and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

3-8
Dell Latitude XPi CD Reference and Troubleshooting Guide
Memory address
line failure
at
address
,
read
value
expecting
value
An installed memory module
may be faulty or improperly
seated.
See “Troubleshooting Memory” found later in this
chapter.
Memory alloca-
tion
error
The software you are attempt-
ing to run is conflicting with the
operating system, another
application program, or a util-
ity.
Turn off the computer, wait 30 seconds, and then
restart it. Try to run the program again. If the problem
persists, contact the software company.
Memory data
line failure
at
address
,
read
value
expecting
value
An installed memory module
may be faulty or improperly
seated.
See “Troubleshooting Memory” found later in this
chapter.
Memory double
word logic
failure at
addres
s, read
value
expect-
ing
value
An installed memory module
may be faulty or improperly
seated.
See “Troubleshooting Memory” found later in this
chapter.
Memory odd/
even logic
failure at
address
, read
value
expect-
ing
value
An installed memory module
may be faulty or improperly
seated.
See “Troubleshooting Memory” found later in this
chapter.
Memory write/
read failure
at
address
,
read
value
expecting
value
An installed memory module
may be faulty or improperly
seated.
See “Troubleshooting Memory” found later in this
chapter.
No boot device
available
The computer cannot find the
diskette or hard-disk drive.
If the diskette drive is your boot device, make sure
there is a bootable diskette in the drive. If the hard-disk
drive is your boot device, make sure the drive is
installed, properly seated, and partitioned as a boot
device.
Table 3-2.
System Error Messages
(Continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the online
System User’s Guide.