Dell PowerEdge M610x Fabric OS Message Reference - Page 113
AN System Messages, AN-1001
View all Dell PowerEdge M610x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
AN System Messages Chapter 3 AN-1001 Message , [AN-1001], ,, ERROR, , Failed to allocate memory: Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Check memory usage on the switch using the memShow command. Restart or power cycle the Action switch. Severity ERROR AN-1002 Message , [AN-1002], ,, ERROR, , Failed to initialize; rc = Probable Cause Indicates that the initialization of the 'trafd' daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR AN-1003 Message , [AN-1003], ,, WARNING, , Latency bottleneck at slot , port . .2f percent of last seconds were affected. Avg. inter-frame time .4f us. Probable Cause For an F_Port, it indicates that the attached device is slow in responding to frames going out of this port. This latency may be inherent in the device or due to heavy workload on the device. For an E_Port, it indicates a downstream primary bottleneck. Recommended Find the Top Talkers in the egress direction from this port and apply Ingress Rate Limiting to one or Action more of them. Severity WARNING Fabric OS Message Reference 37 53-1001767-01