45 HIL-1610 Recommended No action required. Action Severity INFO HIL-1610 Message , [HIL-1610], , FFDC, WARNING, , Fan/PS unit not supplying power, fan speeds not available. Please ensure that the unit has power and the switch is on. Probable Cause Indicates that the power supply is not connected to a power source or it is not switched on or the unit is faulty. Applicable only to Brocade 5100. Recommended Ensure that the power cord is connected to the unit with a valid power source and then switch on Action the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 Message , [HIL-1650], , ERROR, , unable to detect both WWN cards in chassis. Access to WWN halted. Probable Cause One or both of the WWN cards is missing. Both WWN cards must be present for normal operation. Recommended Make sure both WWN cards are inserted. Action Severity ERROR 382 Fabric OS Message Reference 53-1001767-01