Dell PowerEdge M610x Fabric OS Message Reference - Page 334
Ficn-1066, Ficn-1067, Ficn-1068, Ficn-1069
View all Dell PowerEdge M610x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 334 highlights
35 FICN-1066 FICN-1066 Message , [FICN-1066], ,, WARNING, , MemAllocFailed for GEPort= VEport= could not create required structure. Probable Cause Indicates an internal resource limit has been encountered such that additional control block memory could not be allocated. Recommended This is an unexpected event, either the maximum number of emulation devices are already in use Action or there is an internal memory leak, contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], ,, ERROR, , Ingress Abort:Oxid=0x:Abort for CH=0x . Probable Cause Indicates an abort operation has been received from a local FC interface for an emulation CH exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1068 Message , [FICN-1068], ,, ERROR, , Ingress Abort:Oxid=0x:Abort for CU=0x . Probable Cause Indicates an abort operation has been received from a local FC interface for an emulaton CU exchange. Recommended If there were associated IO errors at the same time as this event, please contact your vendor's Action customer support for assistance. Severity ERROR FICN-1069 Message Probable Cause , [FICN-1069], ,, ERROR, , Emulation Configuration Error on TunnelId . Indicates an error has been noted in the FICON configuration. Refer to the string for the nature of the configuration issue. 258 Fabric OS Message Reference 53-1001767-01