41 FSSM-1004 Probable Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade or downgrade was invoked. The new firmware version is not compatiable with the current running version. This causes a disruptive firmware upgrade or downgrade. Recommended For a dual CP system, run the firmwareDownload command to load compatible firmware on the Action standby CP. For details on this command, refer to the Fabric OS Command Reference Manual. Severity INFO 286 Fabric OS Message Reference 53-1001767-01
286
Fabric OS Message Reference
53-1001767-01
FSSM-1004
41
Probable Cause
Indicates that the active control processor (CP) and the standby CP in a dual CP system are running
firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive.
In a switch system, this message is logged when a firmware upgrade or downgrade was invoked.
The new firmware version is not compatiable with the current running version. This causes a
disruptive firmware upgrade or downgrade.
Recommended
Action
For a dual CP system, run the
firmwareDownload
command to load compatible firmware on the
standby CP. For details on this command, refer to the
Fabric OS Command Reference Manual
.
Severity
INFO