Dell PowerEdge M610x Fabric OS Message Reference - Page 147
BL-1037, BL-1038, BL-1039, BL-1041
View all Dell PowerEdge M610x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
BL-1037 7 BL-1037 Message , [BL-1037], ,, CRITICAL, , Faulting chip in slot = , miniS = , port = due to BE/BI port fault. Probable Cause Indicates a fault on the chip and that all ports on the chip have been disabled. Recommended No action is required. Action Severity CRITICAL BL-1038 Message , [BL-1038], ,, CRITICAL, , Inconsistent FPGA image version detected, please restart the switch for recovery. Probable Cause Indicates that the FPGA image version is incompatible with the software version. Recommended Restart the switch. If the message persists, replace the switch. Action Severity CRITICAL BL-1039 Message , [BL-1039], ,, CRITICAL, , Inconsistent FPGA image version detected, faulting the blade in slot . Probable Cause Indicates that the FPGA image version is incompatible with the software version. Recommended Power cycle the blade. If the message persists, replace the blade. Action Severity CRITICAL BL-1041 Message , [BL-1041], ,, CRITICAL, , Dynamic area mode is enabled on default switch, Faulting the blade w/ ID in slot as it does not support this mode. Probable Cause Indicates that the blade does not support dynamic area mode on default switch. Recommended Turn off the dynamic area mode through Configure CLI. Action Severity CRITICAL Fabric OS Message Reference 71 53-1001767-01