Dell PowerEdge M610x Fabric OS Message Reference - Page 359
FSS-1008, network configuration; then try to restore the synchronization by issuing
View all Dell PowerEdge M610x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 359 highlights
40 FSS-1008 Probable Cause Indicates that the Ethernet connection between the active control processor (CP) and standby CP is not healthy. The error occurs when the standby CP does not respond to a request from the active CP within five seconds. This usually indicates a problem with the internal Ethernet connection and a disruption of the synchronization process. Recommended Action Check the Ethernet connection between the active CP and standby CP (interface eth1) by issuing net commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message , [FSS-1008], , SLOT cp-slot-number | CHASSIS, CRITICAL, , FSS Error: . Probable Cause Indicates that an error has occurred. Recommended Run the supportSave command and contact your switch service provider. Action Severity CRITICAL FSS-1009 Message , [FSS-1009], , SLOT cp-slot-number | CHASSIS, ERROR, , FSS Error: . Probable Cause Indicates that an error has occurred. Recommended Run the supportSave command and contact your switch service provider. Action Severity ERROR FSS-1010 Message , [FSS-1010], , SLOT cp-slot-number | CHASSIS, WARNING, , FSS Warning: . Probable Cause Indicates that an error might have occurred. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 283 53-1001767-01