Dell PowerEdge VRTX Chassis Management Controller Version 1.0 for Dell PowerEd - Page 118

Configuring Generic LDAP Directory Service Using RACADM

Page 118 highlights

Configuring Generic LDAP Directory Service Using RACADM To configure the LDAP directory service, use the objects in cfgLdap and cfgLdapRoleGroup RACADM groups. There are many options to configure LDAP logins. In most of the cases, some options can be used with their default settings. NOTE: It is highly recommended to use the racadm testfeature -f LDAP command to test the LDAP settings for first time setups. This feature supports both IPv4 and IPv6. The required property changes include enabling LDAP logins, setting the server FQDN or IP, and configuring the base DN of the LDAP server. • $ racadm config -g cfgLDAP -o cfgLDAPEnable 1 • $ racadm config -g cfgLDAP -o cfgLDAPServer 192.168.0.1 • $ racadm config -g cfgLDAP -o cfgLDAPBaseDN dc= company,dc=com CMC can be configured to optionally query a DNS server for SRV records. If the cfgLDAPSRVLookupEnable property is enabled, the cfgLDAPServer property is ignored. The following query is used to search the DNS for SRV records: _ldap._tcp.domainname.com ldap in the above query is the cfgLDAPSRVLookupServiceName property. cfgLDAPSRVLookupDomainName is configured to be domainname.com. For more information about the RACADM commands, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals. 118

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193

Configuring Generic LDAP Directory Service Using RACADM
To configure the LDAP directory service, use the objects in
cfgLdap
and
cfgLdapRoleGroup
RACADM groups.
There are many options to configure LDAP logins. In most of the cases, some options can be used with their default
settings.
NOTE:
It is highly recommended to use the racadm
testfeature -f LDAP
command to test the LDAP
settings for first time setups. This feature supports both IPv4 and IPv6.
The required property changes include enabling LDAP logins, setting the server FQDN or IP, and configuring the base
DN of the LDAP server.
$ racadm config -g cfgLDAP -o cfgLDAPEnable 1
$ racadm config -g cfgLDAP -o cfgLDAPServer 192.168.0.1
$ racadm config -g cfgLDAP -o cfgLDAPBaseDN dc=
company,dc=com
CMC can be configured to optionally query a DNS server for SRV records. If the
cfgLDAPSRVLookupEnable
property is enabled, the
cfgLDAPServer
property is ignored. The following query is used to search the DNS for SRV
records:
_ldap._tcp.domainname.com
ldap
in the above query is the
cfgLDAPSRVLookupServiceName
property.
cfgLDAPSRVLookupDomainName
is configured to be
domainname.com
.
For more information about the RACADM commands, see the
Chassis Management Controller for PowerEdge VRTX
RACADM Command Line Reference Guide
available at
dell.com/support/manuals
.
118