Dell PowerEdge VRTX Chassis Management Controller Version 1.0 for Dell PowerEd - Page 128

Connecting to Servers or I/O Module Using Connect Command, iDRAC Serial Over LAN SOL functionality.

Page 128 highlights

Table 23. Minicom Settings Setting Description Bps/Par/Bits Hardware flow control Software flow control Terminal emulation Modem dialing and parameter settings Required Setting 115200 8N1 Yes No ANSI Clear the init, reset, connect, and hangup settings so that they are blank Connecting to Servers or I/O Module Using Connect Command CMC can establish a connection to redirect the serial console of a server or I/O module. For servers, serial console redirection can be accomplished using: • CMC command line interface (CLI) or the RACADM connect command. For more information about running the RACADM commands, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide. • iDRAC Web interface serial console redirection feature. • iDRAC Serial Over LAN (SOL) functionality. In a serial, Telnet, SSH console, CMC supports the connect command to establish a serial connection to a server or I/O module. The server serial console contains both the BIOS boot and setup screens, and the operating system serial console. For the I/O module, the switch serial console is available. There is a single IOM on the chassis. CAUTION: When run from the CMC serial console, the connect -b option stays connected until the CMC resets. This connection is a potential security risk. NOTE: The connect command provides the -b (binary) option. The -b option passes raw binary data, and cfgSerialConsoleQuitKey is not used. Additionally, when connecting to a server using the CMC serial console, transitions in the DTR signal (for example, if the serial cable is removed to connect a debugger) will not result in you exiting the application. NOTE: If the IOM does not support console redirection, the connect command displays an empty console. In that case, to return to the CMC console, type the Escape sequence. The default console escape sequence is . To connect to an IOM: connect switch-n where n is an IOM label A1. When you reference the IOM in the connect command, the IOM is mapped to switch as shown in the following table. Table 24. Mapping IO Module to Switches IO Module Label A1 Switch switch-a1 or switch- 1 NOTE: At a time, there can be only one IOM connection per chassis. NOTE: You cannot connect to pass-throughs from the serial console. To connect to a managed-server serial console, run the command connect server-n, where n is 1-4. You can also use the racadm connect server-n command. When you connect to a server using the -b option, binary 128

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193

Table 23. Minicom Settings
Setting Description
Required Setting
Bps/Par/Bits
115200 8N1
Hardware flow control
Yes
Software flow control
No
Terminal emulation
ANSI
Modem dialing and parameter settings
Clear the
init
,
reset
,
connect
, and
hangup
settings so that they are blank
Connecting to Servers or I/O Module Using Connect Command
CMC can establish a connection to redirect the serial console of a server or I/O module.
For servers, serial console redirection can be accomplished using:
CMC command line interface (CLI) or the RACADM
connect
command. For more information about running the
RACADM commands, see the
Chassis Management Controller for PowerEdge VRTX RACADM Command Line
Reference Guide
.
iDRAC Web interface serial console redirection feature.
iDRAC Serial Over LAN (SOL) functionality.
In a serial, Telnet, SSH console, CMC supports the
connect
command to establish a serial connection to a server or
I/O module. The server serial console contains both the BIOS boot and setup screens, and the operating system serial
console. For the I/O module, the switch serial console is available. There is a single IOM on the chassis.
CAUTION: When run from the CMC serial console, the
connect -b
option stays connected until the CMC resets.
This connection is a potential security risk.
NOTE:
The
connect
command provides the
–b
(binary) option. The
–b
option passes raw binary data, and
cfgSerialConsoleQuitKey
is not used. Additionally, when connecting to a server using the CMC serial
console, transitions in the DTR signal (for example, if the serial cable is removed to connect a debugger) will not
result in you exiting the application.
NOTE:
If the IOM does not support console redirection, the
connect
command displays an empty console. In that
case, to return to the CMC console, type the Escape sequence. The default console escape sequence is <Ctrl><\>.
To connect to an IOM:
connect switch-
n
where
n
is an IOM label A1.
When you reference the IOM in the connect command, the IOM is mapped to switch as shown in the following table.
Table 24. Mapping IO Module to Switches
IO Module Label
Switch
A1
switch-a1 or switch- 1
NOTE:
At a time, there can be only one IOM connection per chassis.
NOTE:
You cannot connect to pass-throughs from the serial console.
To connect to a managed-server serial console, run the command
connect server-
n
, where
n
is 1–4. You can also
use the
racadm connect server-n
command. When you connect to a server using the
-b
option, binary
128