Dell PowerEdge VRTX Chassis Management Controller Version 1.0 for Dell PowerEd - Page 185

LCD Module and Server Status Information, Example: Dell Rack System. This is settable via CMC CLI

Page 185 highlights

Status information on the LCD includes descriptive information about the modules in the chassis. The tables in this section describe the information that is displayed for each component. LCD Module and Server Status Information The tables in this section describe status items that are displayed on the front panel LCD for each type of component in the chassis. Table 34. CMC Status Item Description Example: CMC1, CMC2 Name/Location. No Errors If no error occurs then "No Errors" is displayed, else lists error messages. Firmware Version Only displays on an active CMC. Displays Standby for the standby CMC. IP4 Displays current IPv4 enabled state only on an active CMC. IP4 Address: Only displays if IPv4 is enabled only on an active CMC. IP6 Displays current IPv6 enabled state only on an active CMC. IP6 Local Address: Only displays if IPv6 is enabled only on an active CMC. IP6 Global Address: Only displays if IPv6 is enabled only on an active CMC. Table 35. Chassis or Enclosure Status Item User Define Name Error Messages Model Number Power Consumption Peak Power Minimum Power Ambient Temperature Service Tag CMC redundancy mode PSU redundancy mode Description Example: "Dell Rack System". This is settable via CMC CLI or Web GUI. If no errors occur then No Errors is displayed; otherwise error messages are listed, critical errors first, then warnings. Example "PowerEdgeM1000". Current power consumption in watts. Peak power consumed in watts. Minimum power consumed in watts. Current ambient temperature in degrees Celsius. The factory-assigned service tag. Non-Redundant or Redundant. Non-Redundant, AC Redundant, or DC Redundant. 185

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193

Status information
on the LCD includes descriptive information about the modules in the chassis. The tables in this
section describe the information that is displayed for each component.
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in
the chassis.
Table 34. CMC Status
Item
Description
Example: CMC1, CMC2
Name/Location.
No Errors
If no error occurs then “No Errors” is displayed, else lists
error messages.
Firmware Version
Only displays on an active CMC. Displays Standby for the
standby CMC.
IP4 <enabled, disabled>
Displays current IPv4 enabled state only on an active
CMC.
IP4 Address: <address, acquiring>
Only displays if IPv4 is enabled only on an active CMC.
IP6 <enabled, disabled>
Displays current IPv6 enabled state only on an active
CMC.
IP6 Local Address: <address>
Only displays if IPv6 is enabled only on an active CMC.
IP6 Global Address: <address>
Only displays if IPv6 is enabled only on an active CMC.
Table 35. Chassis or Enclosure Status
Item
Description
User Define Name
Example: “Dell Rack System”. This is settable via CMC CLI
or Web GUI.
Error Messages
If no errors occur then No Errors is displayed; otherwise
error messages are listed, critical errors first, then
warnings.
Model Number
Example "PowerEdgeM1000".
Power Consumption
Current power consumption in watts.
Peak Power
Peak power consumed in watts.
Minimum Power
Minimum power consumed in watts.
Ambient Temperature
Current ambient temperature in degrees Celsius.
Service Tag
The factory-assigned service tag.
CMC redundancy mode
Non-Redundant or Redundant.
PSU redundancy mode
Non-Redundant, AC Redundant, or DC Redundant.