Dell PowerVault NX300 Hardware Owner's Manual - Page 40
Alert! System, and UEFI Boot Manager
View all Dell PowerVault NX300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Table 1-3. System Messages (continued) Message Causes Corrective Actions Alert! Power required exceeds PSU wattage. Check PSU and system configuration. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. Alert! Continuing system boot accepts the risk that system may power down without warning. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High Output power supplies to use the components. See "Power Supplies" on page 88. Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Memory Sparing or Memory Check the memory modules Mirroring was enabled in the for failure. See system setup program, but "Troubleshooting System the current configuration Memory" on page 154. does not support redundant Reset the memory setting, memory. A memory module if appropriate. See "Using may be faulty. the System Setup Program and UEFI Boot Manager" on page 57. Alert! System fatal error during previous boot. An error caused the system to Check other system reboot. messages for additional information for possible causes. 40 About Your System