Epson ActionNote 880C User Manual - Fax/Data Modem - Page 25

Commands Preceded by\\, enables data buffering. The settings for this command are used by the modem

Page 25 highlights

2.2b Commands Preceded by\ \An Maximum MNP Block Size Sets maximum block size for MNP connections. Use this command to transmit smaller blocks of data in a reliable link connection, \A0 Sets maximum block size to 64 characters. \A1 Sets maximum block size to 128 characters. \A2 Sets maximum block size to 192 characters. \A3 Sets maximum block size to 256 characters (default) \Bn Transmit Break This command causes the modem to send a break (Attention signal), for a duration specified by 'n', to the remote modem. When n = 0, the default break length is used. n= 0-9 Break length in 100 msec. \Cn Set Auto-reliable Buffer (requires a license from Microcom ® In auto-reliable mode (\N3), this command determines the fallback method and enables data buffering. The settings for this command are used by the modem during the V.42 detection phase. 2 - COMMAND REFERENCE 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

2.2b Commands Preceded by\
\An
Maximum MNP Block Size
Sets
maximum block size for MNP connections. Use this command to transmit
smaller blocks of data in a reliable link connection,
\A0
Sets maximum block size to 64 characters.
\A1
Sets maximum block size to 128 characters.
\A2
Sets maximum block size to 192 characters.
\A3
Sets maximum block size to 256 characters
(default)
\Bn
Transmit Break
This command causes the modem to send a break (Attention signal), for a duration
specified by ’n’, to the remote modem. When n = 0, the default break length is used.
n= 0-9
Break length in 100 msec.
\Cn
Set Auto-reliable Buffer (requires a license from Microcom ®
In auto-reliable mode (\N3), this command determines the fallback method and
enables data buffering. The settings for this command are used by the modem
during the V.42 detection phase.
2 - COMMAND REFERENCE