Fujitsu MAB3091SC Product Manual - Page 31

Environmental specifications, Vibration displacement should be less than 2.5 mm.

Page 31 highlights

2.1.3 Environmental specifications Table 2.2 lists environmental and power requirements. Table 2.2 Environmental/power requirements MAA3182xx MAB3091xx MAB3045xx MAC3091xx Operating 5 to 50°C Non-operating - 40 to 60°C Temperature (*1) DE surface temperature at operating 5 to 55°C Gradient 15°C/h or less Operating 20 to 80%RH Non operating Relative humidity 20 to 80%RH Packaged (inside of a week) 5 to 90%RH Maximum wet bulb temperature 29°C (no condensation) Vibration (*2) Operating (*3) Non-operating (*4) 0.3 mm (5 to 20Hz)/0.5G (20 to 250 Hz) or less 3.1 mm (5 to 20Hz)/5G (20 to 250Hz) or less Packaged 3.1 mm (5 to 20Hz)/5G (20 to 250Hz) or less Shock (*2) Operating Non-operating 50G or less (11 ms half-sin.) 5G (11 ms half-sin.) or less 60G or less (11 ms half-sin) Altitute Operating (above sea level) Non-operating 0 m to 3,000 m (above sea level) 0 m to 12,000 m (above sea level) +12 VDC ±5% Ready (Average) Spin-up, Seek Power requirements Peak within 100 µs at spin-up Input power (*5) +5 VDC ±5% (*6) 0.77 A 2.5 A (Max) 3.0 A 0.43 A 1.8 A (Max) 3.0 A 0.27 A 1.8 A (Max) 3.0 A 0.85 A 2.5 A (Max) 3.0 A Ready Random W/R (about 80 IOPS) 0.75 A 1.1 A Ripple (*7) +5 V 100 mVp-p, +12 V 150 mVp-p MAC3045xx 0.60 A 2.5 A (Max) 3.0 A (*1) For detail condition, see Section 4.1. (*2) Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as possible. (*3) At random seek write/read and default on retry setting with log sweep vibration. (*4) At power-off state after installation Vibration displacement should be less than 2.5 mm. (*5) Input voltages are specified at the connector. 2 - 4 C141-E035-03EN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

C141-E035-03EN
2 - 4
2.1.3
Environmental specifications
Table 2.2 lists environmental and power requirements.
Table 2.2
Environmental/power requirements
MAA3182xx
MAB3091xx
MAB3045xx
MAC3091xx
MAC3045xx
Operating
5 to 50°C
Non-operating
– 40 to 60°C
DE surface
temperature at
operating
5 to 55°C
Gradient
15°C/h or less
Operating
20 to 80%RH
Non operating
20 to 80%RH
Packaged
(inside of a week) 5 to 90%RH
Maximum wet
bulb temperature
29°C (no condensation)
Operating (*3)
0.3 mm (5 to 20Hz)/0.5G (20 to 250 Hz) or less
Non-operating
(*4)
3.1 mm (5 to 20Hz)/5G (20 to 250Hz) or less
Packaged
3.1 mm (5 to 20Hz)/5G (20 to 250Hz) or less
Operating
5G (11 ms half-sin.) or less
Non-operating
50G or less
(11 ms half-sin.)
60G or less (11 ms half-sin)
Operating
0 m to 3,000 m (above sea level)
Non-operating
0 m to 12,000 m (above sea level)
+12 VDC ±5%
Ready (Average)
Spin-up, Seek
Peak within
100
μ
s at spin-up
0.77 A
2.5 A (Max)
3.0 A
0.43 A
1.8 A (Max)
3.0 A
0.27 A
1.8 A (Max)
3.0 A
0.85 A
2.5 A (Max)
3.0 A
0.60 A
2.5 A (Max)
3.0 A
+5 VDC ±5% (*6)
Ready
Random W/R
(about 80 IOPS)
0.75 A
1.1 A
Ripple (*7)
+5 V 100 mVp-p, +12 V 150 mVp-p
(*1)
For detail condition, see Section 4.1.
(*2)
Vibration applied to the drive is measured at near the mounting screw hole on the frame as
much as possible.
(*3)
At random seek write/read and default on retry setting with log sweep vibration.
(*4)
At power-off state after installation
Vibration displacement should be less than 2.5 mm.
(*5)
Input voltages are specified at the connector.
Power
requirements
Input power (*5)
Altitute
(above sea level)
Shock (*2)
Vibration (*2)
Relative humidity
Temperature (*1)