3 Disconnect the AC voltage to the Heating Element by releasing the connector located on the DC Controller. Press down on the connector release with a small, flathead screwdriver (Figure 6-14, callout 1). (Because this is a small space, it is much easier to reach the connector with a screwdriver.) Pull straight out (Figure 6-14, callout 2). 1 2 Figure 6-14 Heating Element removal (2 of 3) EN Internal assemblies 85
EN
Internal assemblies
85
3
Disconnect the AC voltage to the Heating Element by releasing the connector located on the DC
Controller. Press down on the connector release with a small, flathead screwdriver (Figure 6-14,
callout 1). (Because this is a small space, it is much easier to reach the connector with a
screwdriver.) Pull straight out (Figure 6-14, callout 2).
Figure
6-14
Heating Element removal (2 of 3)
1
2