HP ProLiant DL380p HP ProLiant Servers Troubleshooting Guide - Page 127

Invalid Password - System Restricted

Page 127 highlights

Internal CPU Check - Processor Audible Beeps: None Possible Cause: A processor has experienced an internal error. Action: 1. Run Insight Diagnostics ("HP Insight Diagnostics" on page 77). CAUTION: Before removing or replacing any processors, be sure to follow the guidelines provided in "Performing processor procedures in the troubleshooting process (on page 18)." Failure to follow the recommended guidelines can cause damage to the system board, requiring replacement of the system board. 2. Replace any failed components as indicated, including processors and PPMs. Invalid memory types were found on the same node. Please check DIMM compatibility. - Some DIMMs may not be used Description: Invalid or mixed memory types were detected during POST. Action: Use only supported DIMM pairs when populating memory sockets. Refer to the applicable server user guide memory requirements. Invalid Password - System Halted! Audible Beeps: None Possible Cause: An invalid password was entered. Action: Enter a valid password to access the system. Invalid Password - System Restricted! Audible Beeps: None Possible Cause: A valid password that does not have permissions to access the system has been entered. Action: Enter a valid password with the correct permissions. Memory found on unpopulated Node. - Processor is required to be installed for memory to be used. Description: The system detects DIMMs, but is unable to use the DIMMs because a processor is not installed in the corresponding socket. Action: CAUTION: Before installing any processors, be sure to follow the guidelines provided in "Performing processor procedures in the troubleshooting process (on page 18)." Failure to follow the recommended guidelines can cause damage to the system board requiring replacement of the system board. To use the installed DIMMs, install a processor in the corresponding socket. Error messages 127

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Error messages 127
Internal CPU Check - Processor
Audible Beeps
: None
Possible Cause
: A processor has experienced an internal error.
Action
:
1.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
).
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
18
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
2.
Replace any failed components as indicated, including processors and PPMs.
Invalid memory types were found on the same node. Please check DIMM
compatibility. - Some DIMMs may not be used
Description
: Invalid or mixed memory types were detected during POST.
Action:
Use only supported DIMM pairs when populating memory sockets. Refer to the applicable server user
guide memory requirements.
Invalid Password - System Halted!
Audible Beeps
: None
Possible Cause
: An invalid password was entered.
Action
: Enter a valid password to access the system.
Invalid Password - System Restricted!
Audible Beeps
: None
Possible Cause
: A valid password that does not have permissions to access the system has been entered.
Action
: Enter a valid password with the correct permissions.
Memory found on unpopulated Node. — Processor is required to be installed for
memory to be used.
Description
: The system detects DIMMs, but is unable to use the DIMMs because a processor is not installed
in the corresponding socket.
Action:
CAUTION:
Before installing any processors, be sure to follow the guidelines provided in
"Performing processor procedures in the troubleshooting process (on page
18
)." Failure to follow
the recommended guidelines can cause damage to the system board requiring replacement of the
system board.
To use the installed DIMMs, install a processor in the corresponding socket.