HP BladeSystem p-Class infrastructure error codes

Page 176 highlights

System Fans Not Redundant Event Type: Fans not redundant Action: Add a fan or replace the failed fan. System Overheating (Zone X, Location) Event Type: Overheating condition Action: Check fans. System Power Supplies Not Redundant Event Type: Power supply not redundant Action: Add a power supply or replace the failed power supply. System Power Supply Failure (Power Supply X) Event Type: Power supply failure Action: Replace the power supply. Unrecoverable Host Bus Data Parity Error... ...Unrecoverable Host Bus Address Parity Error Event Type: Host bus error CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. If you believe the system board requires replacement, contact HP Technical Support ("Contacting HP" on page 187) before proceeding. Action: Replace the board on which the processor is installed. Uncorrectable Memory Error (Slot X, Memory Module Y)... ...Uncorrectable Memory Error (System Memory) Uncorrectable Memory Error (Memory Module Unknown) Event Type: Uncorrectable error Action: Replace the memory module. If the problem persists, replace the memory board. HP BladeSystem p-Class infrastructure error codes The server blade management modules and power management modules contain service ports that enable service personnel to gather fault information. To gather the fault information: 1. Connect to the service port. For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info). Error messages 176

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Error messages 176
System Fans Not Redundant
Event Type
: Fans not redundant
Action
: Add a fan or replace the failed fan.
System Overheating (Zone X, Location)
Event Type
: Overheating condition
Action
: Check fans.
System Power Supplies Not Redundant
Event Type
: Power supply not redundant
Action
: Add a power supply or replace the failed power supply.
System Power Supply Failure (Power Supply X)
Event Type
: Power supply failure
Action
: Replace the power supply.
Unrecoverable Host Bus Data Parity Error...
...Unrecoverable Host Bus Address Parity Error
Event Type
: Host bus error
CAUTION:
Only authorized technicians trained by HP should attempt to remove the system
board. If you believe the system board requires replacement, contact HP Technical Support
("
Contacting HP
" on page
187
) before proceeding.
Action
: Replace the board on which the processor is installed.
Uncorrectable Memory Error (Slot X, Memory Module Y)...
...Uncorrectable Memory Error (System Memory)
Uncorrectable Memory Error (Memory Module Unknown)
Event Type
: Uncorrectable error
Action
: Replace the memory module. If the problem persists, replace the memory board.
HP BladeSystem p-Class infrastructure error codes
The server blade management modules and power management modules contain service ports that enable
service personnel to gather fault information.
To gather the fault information:
1.
Connect to the service port. For more information, refer to the
HP BladeSystem Maintenance and
Service Guide
on the HP website
(
).