1743-Slot X Drive Array - Logical Drive Erase Operation(s) are Queued... ...Logical drives will temporarily go offline while being erased. Audible Beeps: None Possible Cause: The drives being erased are offline. Action: Do one of the following: • Wait for the erase process to complete before using the logical drive. • Abort the erase process using ACU ("Array Configuration Utility" on page 72). 1744-Slot X Drive Array - Drive Erase Operation In Progress (or Queued)... ...The following disk drive(s) will be blank upon completion: (followed by a list of drives) Audible Beeps: None Possible Cause: A drive erase operation was previously initiated by the user and is in progress or is scheduled for all drives in the list. Action: None required 1745-Slot X Drive Array - Drive Erase Operation Completed... ...The following disk drive(s) have been erased and will remain offline until hot-replaced or re-enabled by the Array Configuration Utility: (followed by a list of drives) Audible Beeps: None Possible Cause: The drive erase operation was successfully completed, and the drives are being held in an offline state to ensure that the drives remain blank until re-enabled by the user. Action: Replace each drive in the list or re-enable each drive in the list using one of the following methods: • Use the Array Configuration Utility (on page 72) (all drive types). • Perform hot-plug removal and reinstallation (hot-plug hard drives only). 1746-Slot X Drive Array - Unsupported Storage Connection Detected... ...SAS connection via expander is not supported on this controller model. Access to all storage has been disabled until the expander and connections beyond it are detached or controller is upgraded. Audible Beeps: None Possible Cause: The controller or firmware version does not support the attached drive enclosure. Action: Upgrade the controller, or detach the expander-based storage connections. 1747-Slot X Drive Array - Unsupported Array Configuration Detected... (followed by one of the following:) ...* More logical drive(s) configured than what this controller model can support when the memory module is detached * One or more logical drive(s) are configured in positions that this controller does not support when the memory module is detached. * One or more logical drive(s) are configured for RAID fault tolerance level(s) that are not supported when the memory module is detached. Error messages 157

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Error messages 157
1743-Slot X Drive Array - Logical Drive Erase Operation(s) are Queued...
...Logical drives will temporarily go offline while being erased.
Audible Beeps
: None
Possible Cause
: The drives being erased are offline.
Action
: Do one of the following:
Wait for the erase process to complete before using the logical drive.
Abort the erase process using ACU ("
Array Configuration Utility
" on page
72
).
1744-Slot X Drive Array - Drive Erase Operation In Progress (or Queued)...
...The following disk drive(s) will be blank upon completion: (followed by a list of drives)
Audible Beeps
: None
Possible Cause
: A drive erase operation was previously initiated by the user and is in progress or is
scheduled for all drives in the list.
Action
:
None required
1745-Slot X Drive Array - Drive Erase Operation Completed...
...The following disk drive(s) have been erased and will remain offline until hot-replaced or re-enabled by the Array
Configuration Utility:
(followed by a list of drives)
Audible Beeps
: None
Possible Cause
: The drive erase operation was successfully completed, and the drives are being held in an
offline state to ensure that the drives remain blank until re-enabled by the user.
Action
: Replace each drive in the list or re-enable each drive in the list using one of the following methods:
Use the Array Configuration Utility (on page
72
) (all drive types).
Perform hot-plug removal and reinstallation (hot-plug hard drives only).
1746-Slot X Drive Array - Unsupported Storage Connection Detected...
...SAS connection via expander is not supported on this controller model. Access to all storage has been disabled until
the expander and connections beyond it are detached or controller is upgraded.
Audible Beeps
: None
Possible Cause
: The controller or firmware version does not support the attached drive enclosure.
Action
: Upgrade the controller, or detach the expander-based storage connections.
1747-Slot X Drive Array - Unsupported Array Configuration Detected...
(followed by one of the following:)
...*
More logical drive(s) configured than what this controller model can support when the memory module is
detached
*
One or more logical drive(s) are configured in positions that this controller does not support when the memory
module is detached.
*
One or more logical drive(s) are configured for RAID fault tolerance level(s) that are not supported when the memory
module is detached.