HP StorageWorks P2000 HP StorageWorks P2000 G3 MSA System CLI Reference Guide - Page 157
Temperature Exceeded, Partner Notify, Auto Write Back
View all HP StorageWorks P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 157 highlights
Temperature Exceeded Shows whether the system forces a controller shutdown when a temperature is detected that exceeds system threshold limits. Partner Notify Shows whether the partner controller is notified when a trigger condition occurs. Auto Write Back Shows whether the cache mode automatically changes to write-back after the trigger condition is cleared. Example Show advanced system-configuration settings: # show advanced-settings Background Scrub: Enabled Partner Firmware Upgrade: Disabled Utility Priority: High SMART: Enabled Dynamic Spare Configuration: Disabled Enclosure Polling Rate: 5 Host Control of Caching: Enabled Sync Cache Mode: Immediate Missing LUN Response: Not Ready Controller Failure: Disabled SuperCap Failure: Enabled CompactFlash Failure: Enabled Power Supply Failure: Disabled Fan Failure: Disabled Temperature Exceeded: Disabled Partner Notify: Disabled Auto Write Back: Enabled See also • set advanced-settings HP StorageWorks P2000 G3 MSA System CLI Reference Guide 157