HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 133
FRU Codes, Table 13 Disk Array FRU Codes
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Troubleshooting FRU Codes Troubleshooting FRU Codes Each replaceable hardware assembly in the disk array is assigned a FRU (Field Replaceable Unit) code. These FRU codes are used to identify suspect hardware in the controller event logs. Table 13 lists the FRU codes and the hardware assembly associated with each. FRU Code 0 1 2 3 4 5 6 7 8 9 10 11 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 192 193 194 195 Table 13 Disk Array FRU Codes Hardware Assembly Disk in slot A1 Disk in slot B1 Disk in slot A2 Disk in slot B2 Disk in slot A3 Disk in slot B3 Disk in slot A4 Disk in slot B4 Disk in slot A5 Disk in slot B5 Disk in slot A6 Disk in slot B6 Reporting Controller1, or No FRU. First installable SIMM on X controller Second installable SIMM on X controller First installable SIMM on Y controller Second installable SIMM on Y controller Other (non-reporting2) controller Battery Fan 1 Fan 2 Fan 3 Power Supply 1 Power Supply 2 Controller X Controller Y Power Supply 3 Internal SCSI Bus 0 Internal SCSI Bus 1 Internal SCSI Bus 2 Internal SCSI Bus 3 1 The reporting controller is the controller identified in the Component Specific ID field of the Controller Error Event specific data. 133