HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 143
Ignore - See, State For Down
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 36/0x24 Illegal Drive State For Down Command N NA None An attempt to down a disk failed. Downing the disk would have resulted in loss of redundancy or data unavailability. Make sure the correct down type is specified when performing the command. 37/0x25 Recovered With RAID 5 Retries Y Ignore - See None accompanying errors Retries were used successful completion of a read or write to RAID 5 space. 38/0x26 Recovered With RAID 5 Redundancy Y Ignore - See None accompanying errors Redundancy was used in the successful completion of a read or write to RAID 5 space. 39/0x27 Unavailable Data Detected By RAID 5 Y See None Accompanying Errors An attempt to read or write failed because the array is in a data unavailable state. This may be a result of removing disk drives. Reinstall any disks that may have been removed. 40/0x28 Send Diagnostic N Single Controller Self Test Failure Occurrence The current system state and warnings indicate that the self test should return bad status. Check system state and warning states for more information. 41/0x29 Invalid Pass Through N NA None The host attempted an execute pass through command without a valid Set Pass Through Mode command preceding. 143