HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 168
RAM For Image
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 168 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 167/0xa7 Insufficient Y Ignore - None RAM For Image Operator error Upload or accompanying errors This errors occurs if a disk set has been moved from a controller with more RAM to a controller with less RAM. Consequently, the current RAM configuration is not large enough to hold the NVRAM image stored on disk. More RAM can be added to the controller to correct this problem 168/0xa8 Internal SCSI Queuing Disabled Y Immediate Disk Drive Performance Problem - Unsupported Disk This event indicates that the controller couldn't set the SCSI configuration settings for the disk drive correctly. This could be caused by a failing disk drive, or the use of an unsupported disk drive. 169/0xa9 Internal SCSI Disconnects Disabled Y Immediate Disk Drive Performance Problem - Unsupported Disk The controller could not configure the disk drive to disable disconnects during data transfer phase. This will cause the interface driver to disable disconnects on the channel, thus causing degraded drive performance. This event may also indicate that the controller could not enable queuing on this drive so the interface driver will disable disconnects on the channel. This is typically caused by using an unsupported disk drive that the controller cannot configure properly. 168